Eaton EDR-5000-2B0LA1 Distribution Relay - Mbus TCP / DNP3 TCP

Part Number: EDR-5000-2B0LA1
Manufacturer
Eaton
Part number
EDR-5000-2B0LA1

Quick Summary

Eaton distribution relay EDR-5000-2B0LA1 delivers advanced feeder protection and remote monitoring for industrial control systems. This solution addresses the common challenge of fragmented telemetry by centralizing protection logic and data communication over robust Ethernet paths. Compliance considerations typically include standard safety and performance certifications; verify exact markings in the Eaton datasheet. With 16 inputs and 11 outputs and support for Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet, it fits into modern feeder protection workflows and Industry 4.0 monitoring strategies. The result is faster diagnostics, tighter control of protection settings, and reduced downtime across distributed networks and critical infrastructure.

Product Information

Extended Description

EDR-5000-2B0LA1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11,Feeder, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B0LA1
UPC
786679142950
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
1
I/O options
Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Current Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: 16 inputs and 11 outputs enable expansive feeder protection coverage and granular monitoring for large electrical distributions, reducing blind spots and enabling precise coordination with upstream devices in high-density panels. This directly translates to improved reliability and faster fault isolation in critical facilities such as data centers or manufacturing lines. Application: feeder protection with scalable I/O for growing substations and complex control schemes. Feature → Business Impact → Application: Wide power-supply range (19-300Vdc, 40-250Vac) supports both DC and AC networks, simplifying procurement and installation in mixed environments while maintaining consistent protection logic. This minimizes spare-part costs and accelerates commissioning in multinational facilities. Application: multinational industrial campuses and retrofit projects. Feature → Business Impact → Application: Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet enables secure, remote access and interoperability with SCADA systems, reducing onsite visits and enabling centralized diagnostics across multiple substations. Application: asset-wide monitoring and predictive maintenance programs. Feature → Business Impact → Application: Zone selective interlocking (1) improves protection selectivity, enabling upstream feeders to trip only when necessary, cutting unnecessary outages and improving system availability. Application: high-availability process plants. Feature → Business Impact → Application: Trip Coil Monitor IRIG-B and removable terminals simplify maintenance, increase reliability, and speed up field upgrades without disrupting ongoing operations. Application: upgrade cycles and downtime-sensitive installations. Feature → Business Impact → Application: Projection mounting supports robust, space-efficient installation in compact switchgear and control panels, reducing enclosure footprint and simplifying retrofits in legacy systems. Application: retrofit and refurbishment projects. Feature → Business Impact → Application: 50/60 Hz compatibility ensures seamless operation with common industrial power systems worldwide, protecting investments during global deployments. Application: multinational facilities and export-oriented manufacturing.

Get a Quick Quote for a Eaton EDR-5000-2B0LA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2B0LA1? Enquire Now

FAQs

Start with verifying the panel’s quadrature for the 19-300Vdc and 40-250Vac supply. The unit uses removable terminals and projection mounting, which simplifies field wiring and alignment. Plan for LC duplex fiber connections to enable Mbus TCP or DNP3 TCP/UDP communication to your SCADA. Ensure proper torque during terminal connections and perform a site commissioning test to validate protection logic sequencing across all 16 inputs and 11 outputs.
Critical specs include a wide power-supply range of 19-300Vdc and 40-250Vac, 50/60 Hz operation, and configurable phase currents of 5A and 1A. The unit provides 16 inputs and 11 outputs, with communications via Mbus TCP or DNP3 TCP/UDP over LC duplex fiber. This combination supports both local protection schemes and remote telemetry, while maintaining compatibility with mixed DC/AC networks in industrial plants.
Yes, the EDR-5000-2B0LA1 offers DNP3 TCP support and Mbus TCP communication over fiber, facilitating integration with modern SCADA systems. Its rugged design and fiber optic Ethernet option improve immunity to EMI and voltage transients common in industrial environments. For field deployments, confirm fiber termination, shielding, and enclosure ratings to meet site-specific environmental requirements.
Verify the exact compliance markings and certifications from Eaton’s official datasheet for this model. The product listing indicates manufacturer-listed compliances and a standard Eaton warranty policy. When evaluating for regulatory needs, confirm CE markings, safety standards, and any industry-specific requirements with your compliance team and the Eaton specification sheet to ensure full alignment with your facility’s standards.
The EDR-5000-2B0LA1 enables faster fault isolation and centralized monitoring, which directly reduces unplanned outages and maintenance visits. The combination of 16 inputs and 11 outputs supports scalable protection schemes, while fiber-based communication minimizes downtime due to communication faults. In practice, this leads to lowerMean Time To Repair (MTTR) and improved overall plant availability, translating into measurable energy efficiency and operational productivity gains.