Eaton EDR-5000-2B1CA0 Distribution Relay - Modbus TCP

Part Number: EDR-5000-2B1CA0
Manufacturer
Eaton
Part number
EDR-5000-2B1CA0

Quick Summary

Eaton distribution relay EDR-5000-2B1CA0 is a robust feeder protection device designed for industrial power networks. It simplifies protection setpoints across multiple feeders, reducing fault isolation times and improving system availability. This relay supports Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45, with 16 inputs and 11 outputs, enabling scalable protection and real-time monitoring. When selecting protection gear, verify manufacturer guidance on certifications and approvals, and consider CE compliance, SIL readiness, and enclosure IP ratings appropriate to your installation. In practice, users benefit from tighter protection coordination, remote configuration via PowerPort-E, and compatibility with modern OT/IT networks, delivering safer operations and lower lifecycle costs for data centers, manufacturing floors, and distribution sites.

Product Information

Extended Description

EDR-5000-2B1CA0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11,Feeder, , over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil MonitorSensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B1CA0
UPC
786679143681
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: 16 inputs and 11 outputs provide a flexible protection matrix, reducing panel footprint and wiring complexity while enabling advanced feeder protection and metering for large facilities. This translates to faster fault isolation, improved protection coordination, and measurable downtime reductions in manufacturing plants and data centers. Feature → Business Impact → Application: Power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz compatibility ensures reliable operation across diverse power environments, minimizing spare parts and simplifying procurement for multi-site rolls. Application: Industrial facilities with mixed voltage architectures benefit from a single protective solution across DC and AC networks. Feature → Business Impact → Application: Modbus TCP or DNP3 TCP/UDP communication over Ethernet RJ45 enables remote monitoring, configuration, and integration with SCADA/HMI systems, reducing on-site maintenance and accelerating commissioning for feeders and substations. Application: Critical infrastructure and manufacturing lines requiring centralized control. Feature → Business Impact → Application: I/O options including IRIG-B Trip Coil Monitor and Sensitive Ground Input improve fault triage and time synchronization, enhancing coordination with upstream protection and data logging for regulatory audits. Application: Utility-like feeder protection in complex plant layouts. Feature → Business Impact → Application: Semi-flush mounting and removable terminals streamline installation and serviceability, cutting commissioning time and maintenance costs in retrofit projects for existing Eaton-based panels. Application: Upgrades and new installs where fast deployment and easy field servicing matter. Feature → Business Impact → Application: 16 inputs and 11 outputs support comprehensive protection and metering schemes (Power Protection, Voltage Protection, and Current Protection), enabling precise protection curves and energy monitoring for performance analytics. Application: Power quality improvement and energy management in industrial facilities.

Get a Quick Quote for a Eaton EDR-5000-2B1CA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2B1CA0? Enquire Now

FAQs

The EDR-5000-2B1CA0 offers 16 inputs and 11 outputs, removable terminals, and a semi-flush mounting method, simplifying retrofit and expansion. Its power range supports both DC and AC supplies (19-300Vdc, 40-250Vac), enabling straightforward integration with existing Eaton protection schemes and minimizing cabinet rework while preserving reliable feeder protection.
Key specs include voltage sensing inputs of 1, phase current options of 5A and 1A, a versatile power supply range (19-300Vdc / 40-250Vac) at 50/60 Hz, 16 inputs and 11 outputs, and Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45 for secure remote communications and integration with SCADA systems.
Yes. With 16 inputs and 11 outputs, configurable protection and metering across voltage and current domains, and Ethernet-based communication for remote supervision, the EDR-5000-2B1CA0 is well-suited for feeder protection in manufacturing plants, data centers, and large distribution panels, enabling faster fault isolation and improved system reliability.
Compliances are listed as 'Contact Manufacturer' on the data sheet. For regulatory alignment, verify with Eaton directly regarding CE marking, IP enclosure ratings, and SIL readiness based on your installation and safety requirements, using Eaton’s specification sheet as the authoritative reference.
Expected ROI stems from reduced downtime via faster fault isolation, lower maintenance visits due to remote monitoring and configuration (Modbus TCP/DNP3), and easier commissioning with PowerPort-E. The result is improved equipment uptime, safer operations, and lower lifecycle costs across multi-site feeder networks.