Eaton distribution relay EDR-5000-2B1EB1 - Profibus-DP

Part Number: EDR-5000-2B1EB1
Manufacturer
Eaton
Part number
EDR-5000-2B1EB1

Quick Summary

Eaton distribution relay EDR-5000-2B1EB1 is a compact, multi‑feeder protection device designed to manage feeder supervision and signaling in industrial control panels. Engineers often face wiring complexity and slow fault isolation when expanding protection across multiple feeders, which this unit helps reduce. Specific certifications and compliance status are determined by the manufacturer and may vary by configuration, with CE and regional approvals typically referenced on the datasheet. By leveraging Profibus-DP over D-Sub/RS-485, a wide input range, and flexible I/O, the solution delivers reliable protection, streamlined wiring, and scalable performance that supports efficient panel design and maintenance planning.

Product Information

Extended Description

EDR-5000-2B1EB1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11,Feeder over D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B1EB1
UPC
786679143926
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
1
I/O options
IRIG-B Sensitive Ground Input Trip Coil Monitor
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Voltage Protection and Metering Current Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Feature: 16 inputs and 11 outputs provide robust I/O capacity for feeder protection and metering. Business impact: Enables centralized protection logic with fewer modules, reducing panel space and wiring costs. Application: Ideal for multi‑feeder distribution where centralized monitoring is required. Feature: Power supply range of 19-300 VDC and 40-250 VAC at 50/60 Hz. Business impact: Supports diverse plant power architectures and simplifies procurement. Application: Suitable for mixed DC and AC powered protection schemes in industrial facilities. Feature: Profibus-DP over D-Sub / RS-485 communication. Business impact: Reliable, standards-based remote signaling and integration with PLCs. Application: Widely used in process and power distribution networks. Feature: Conformal coated circuit boards and projection mounting. Business impact: Enhanced reliability in harsh environments and easier installation in cabinet interiors. Application: Ideal for outdoor or dirty environments where moisture and contaminants are concerns. Feature: I/O options including IRIG-B, Sensitive Ground Input, Trip Coil Monitor. Business impact: Expanded diagnostic and trip verification capabilities reduce downtime. Application: Critical protection schemes requiring precise timing and ground fault monitoring. Feature: Zone selective interlocking (1). Business impact: Faster fault identification and reduced outage impact on overload events. Application: Power distribution networks that demand selective feeder control. Feature: 5 A and 1 A current sensing inputs and 1 sensing input channel. Business impact: Accurate current protection and metering with clear visibility into feeder health. Application: Protection schemes that rely on precise current measurement. Feature: 50/60 Hz compatibility and modular I/O for easy field service. Business impact: Smooth integration with existing plant controls and straightforward maintenance. Application: Industrial automation environments with mixed legacy equipment.

Get a Quick Quote for a Eaton EDR-5000-2B1EB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2B1EB1? Enquire Now

FAQs

Begin with the projection mounting method and secure removable terminals for straightforward maintenance. Connect 16 inputs and 11 outputs to corresponding feeder circuits, wire the power supply across 19–300VDC or 40–250VAC, and link Profibus-DP over D-Sub / RS-485 to your PLC. The design supports efficient wire routing and minimizes field wiring errors.
Confirm voltage supply compatibility (19–300 VDC, 40–250 VAC) and frequency (50/60 Hz). Check that you have 16 inputs and 11 outputs configured for your feeders, and ensure Profibus‑DP communication is mapped correctly to the control system. Pay attention to voltage sensing inputs and current sensing ranges (5 A and 1 A) for accurate protection logic.
Yes. The model includes Zone Selective Interlocking capability and one interlock channel, enabling faster fault isolation and reduced outage impact. When integrated with compatible protection relays and a PLC, you can implement selective feeder tripping while preserving overall system reliability.
Manufacturer guidance governs certifications and region‑specific approvals; refer to the datasheet and product page for CE, SIL, IP considerations, and any country‑level clearances. If your application requires strict compliance, contact Eaton support or your regional distributor to confirm the exact certifications for your configuration.
Maintenance benefits come from removable terminals, conformal coating for rugged environments, and a compact form factor that reduces cabinet space. ROI improves through simplified wiring, faster fault diagnosis (via built‑in diagnostics and shared communication with PLCs), and scalable I/O for future expansion without a full system redesign.