Eaton EDR-5000-2B1GA0 Distribution Relay - RS-485 Modbus/DNP3
Part Number: EDR-5000-2B1GA0
Quick Summary
Eaton distribution relay is a versatile feeder controller that protects feeders and enables metering in industrial power systems. Integrating protection, metering, and remote communication can be challenging, especially when coordinating with SCADA and modern protocols. Common certifications for this class of device include CE marking and SIL-rated options, with IP ratings depending on enclosure—confirm exact specifications with Eaton. The EDR-5000-2B1GA0 supports Modbus RTU or DNP3 RTU over RS-485 and offers 16 inputs with 11 outputs, enabling comprehensive feeder monitoring and control. Its wide power range, 19–300 Vdc and 40–250 Vac, ensures compatibility across global installations, delivering reliable protection while simplifying procurement, installation, and maintenance.
Product Information
Extended Description
EDR-5000-2B1GA0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11,Feeder D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B1GA0
UPC
786679144114
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
IRIG-B Sensitive Ground Input Trip Coil Monitor
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - EDR-5000-2B1GA0
With 16 inputs and 11 outputs, the EDR-5000-2B1GA0 consolidates sensing, protection, and signaling in a single unit, reducing the need for additional I/O modules and wiring, while shortening commissioning time. This translates to faster fault isolation and improved MTTR in feeder panels. The support for Modbus RTU or DNP3 RTU over RS-485 enables straightforward SCADA integration, empowering remote configuration, monitoring, and control to boost uptime and visibility across the plant network. The device’s power supply range of 19-300 Vdc and 40-250 Vac, along with 50/60 Hz compatibility, accommodates diverse global sites, lowering procurement complexity and enabling one relays family for multiple facilities. Removable terminals and semi-flush mounting simplify installation and maintenance, reducing wiring errors and downtime during service. IRIG-B options and Sensitive Ground Input expand measurement capabilities for critical protection schemes in data centers and manufacturing environments. Zone Selective Interlocking (ZSI) capability supports coordinated protection, narrowing fault zones and improving reliability in multi-section feeders.
Get a Quick Quote for a Eaton EDR-5000-2B1GA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-5000-2B1GA0?
Enquire Now
FAQs
Begin by confirming panel space for the 16 input and 11 output I/O, then use the removable terminals for straightforward wiring. Mount the unit semi-flush to the panel and connect the RS-485 Modbus or DNP3 lines to the D-Sub connector. After wiring, verify the 19–300 Vdc or 40–250 Vac power supply, then perform configuration via the built-in interface or PowerPort-E where available.
The EDR-5000 supports Modbus RTU or DNP3 RTU over RS-485 via a D-Sub connector. Configuration is performed through Eaton’s configuration tools (e.g., PowerPort-E) or the device’s onboard interface, enabling address assignment, register mapping, and scada integration. This enables seamless data exchange with existing PLCs and SCADA systems for monitoring and control.
Yes. The unit includes Zone Selective Interlocking capability (ZSI) with a configurable channel count, allowing coordinated tripping and reduced cascading faults in multi-section feeder schemes. For best results, pair ZSI settings with accurate current sensing inputs and Relay-to-PLC coordination to ensure reliable selective protection in motor control centers.
The EDR-5000 supports a dual power range: 19–300 Vdc and 40–250 Vac, with a 50/60 Hz frequency rating. It provides 16 current sensing inputs, 1 current sensing input, and 5 A/1 A phase current options for protection and metering. The device is designed for feeder environments, enabling mixed-supply installations without multiple units.
Warranty follows Eaton’s policy: 25-000, one year from installation or eighteen months from shipment, whichever occurs first. Compliance information is listed as 'Contact Manufacturer' for this model, so verify regional certifications (CE, SIL, IP) and enclosure requirements with Eaton prior to purchase to ensure alignment with local regulations and customer standards.