Eaton EDR-5000-2B1GA1 Distribution Relay - RS485

Part Number: EDR-5000-2B1GA1
Manufacturer
Eaton
Part number
EDR-5000-2B1GA1

Quick Summary

Eaton distribution relay EDR-5000-2B1GA1 protects feeders while delivering real-time monitoring for industrial power networks. Engineers often struggle to coordinate protection schemes while maintaining reliable communications over RS485. Certifications vary by installation; confirm CE, SIL and IP ratings with the manufacturer to ensure compliance. In practice, this device enables Modbus RTU or DNP3 RTU over RS485, delivering business value through improved protection coordination, faster fault isolation, and enhanced visibility of electrical parameters. This combination supports scalable feeder protection, efficient commissioning, and seamless integration with existing SCADA and EMS systems. Support for global power architectures further simplifies procurement and installation across sites.

Product Information

Extended Description

EDR-5000-2B1GA1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11,Feeder D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B1GA1
UPC
786679144206
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Feature: 16 inputs and 11 outputs enable comprehensive protection logic without sprawling wiring, reducing panel complexity and wiring errors. Business impact: Faster commissioning and clearer fault diagnostics in feeder circuits boost uptime for manufacturing lines and critical facilities. Application: Ideal for substations and data centers where multiple protection zones share a single relay. Feature: Power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz operation supports global installations. Business impact: Simplified procurement and consistent relay timing across regions. Application: Suitable for mixed-voltage sites and retrofit projects. Feature: Modbus RTU or DNP3 RTU over RS-485 communications enables seamless SCADA integration. Business impact: Centralized monitoring and faster fault dispatch reduce downtime. Application: Remote diagnostics and alarm management in plant rooms. Feature: Projection mounting and removable terminals ease installation and maintenance. Business impact: Reduced labor costs and faster panel upgrades. Application: Retrofit and new builds with limited enclosure space. Feature: Zone selective interlocking, 1 ISI channel, and IRIG-B trip coil monitor options enhance protection coordination. Business impact: Targeted tripping minimizes collateral damage and improves system reliability. Application: Multi-feeder protection schemes in large facilities. Warranty: Eaton’s standard policy of 25-000 provides one year from installation or eighteen months from shipment, whichever comes first. Compliance: Manufacturer-confirmed compliances ensure site-specific regulatory alignment. This combination of features strengthens overall equipment effectiveness, supports compliant deployments, and delivers measurable efficiency gains across industrial power networks.

Get a Quick Quote for a Eaton EDR-5000-2B1GA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2B1GA1? Enquire Now

FAQs

Begin by mounting the unit in a projection-ready enclosure and securing it with the recommended hardware. Connect the 16 inputs and 11 outputs to the feeder circuits, then attach the removable terminals for ease of maintenance. Power the relay from 19-300 Vdc or 40-250 Vac and verify 50/60 Hz operation. Finally, configure Modbus RTU or DNP3 RTU over RS485 for SCADA communication and load testing.
The relay supports Modbus RTU or DNP3 RTU communications over a D-Sub RS-485 interface. This enables straightforward integration with common SCADA and EMS systems, remote fault reporting, and centralized monitoring without extensive protocol conversion or custom gateways.
Yes, the EDR-5000-2B1GA1 includes Zone Selective Interlocking. This capability coordinates tripping across multiple feeders, reducing the likelihood of unnecessary outages and targeting fault zones more precisely. It improves system reliability in facilities with complex feeder networks and helps protect critical loads.
Power input covers a wide range: 19-300 Vdc or 40-250 Vac with 50/60 Hz. The device includes one current sensing input and a total of 16 inputs with 11 outputs. It supports I/O options like IRIG-B, Trip Coil Monitor, and Sensitive Ground Input, enabling flexible protection schemes across varied electrical environments.
Warranty follows Eaton’s policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. Compliance information is provided by the manufacturer, so verify CE, SIL, and IP ratings based on your installation requirements to ensure regulatory alignment and site acceptance.