Eaton distribution relay EDR-5000-2B1KA0 - 50/60 Hz

Part Number: EDR-5000-2B1KA0
Manufacturer
Eaton
Part number
EDR-5000-2B1KA0

Quick Summary

The Eaton distribution relay EDR-5000-2B1KA0 provides feeder protection for industrial power systems. It is designed to coordinate trip signals across multiple feeders, reducing fault duration and limiting damage. In practice, buyers frequently seek CE marking, SIL-rated functionality, and robust IP-rated enclosures, so confirm certifications with Eaton. The unit supports 16 inputs and 11 outputs, a wide power range, Modbus/DNP3 TCP over fiber, and removable terminals, enabling scalable protection with faster commissioning and lower maintenance. These features translate into measurable business value through improved uptime, safer operations, and a shorter path from design to deployment.

Product Information

Extended Description

EDR-5000-2B1KA0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11, Removable, Feeder, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B1KA0
UPC
786679144497
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Removable terminals and a 16-in/11-out configuration streamline installation and future expansion, enabling quicker commissioning and simpler maintenance, which reduces field labor costs. The broad power range of 19-300 Vdc and 40-250 Vac, combined with 50/60 Hz compatibility, supports diverse plant architectures, minimizing the need for auxiliary power conditioning and enabling a single protection platform across the facility. IRIG-B Trip Coil Monitor and Sensitive Ground Input options enhance fault detection and ground fault tracing, improving safeguarding of critical equipment and reducing the risk of nuisance trips in complex networks. Modbus and DNP3 TCP over LC duplex fiber optic Ethernet provides robust, low-latency communications for remote monitoring and centralized protection coordination, reducing SCADA integration time. Semi-flush mounting and removable terminals simplify retrofit projects and serviceability, decreasing downtime during upgrades and routine maintenance. The 5A/1A phase current sensing and zone selective interlocking (ZSI) capability support precise coordination, improving selective tripping and system reliability. These features collectively enable measurable improvements in uptime, safety, and total cost of ownership for feeders and distribution networks.

Get a Quick Quote for a Eaton EDR-5000-2B1KA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2B1KA0? Enquire Now

FAQs

The EDR-5000-2B1KA0 supports Modbus and DNP3 TCP communications over LC duplex fiber optic Ethernet, enabling fast, reliable remote monitoring and centralized protection coordination across feeders and substations.
It features 16 inputs and 11 outputs with a power supply range of 19-300 Vdc and 40-250 Vac, operating at 50/60 Hz for broad compatibility in mixed power environments.
Yes. With 5A/1A phase current sensing, zone selective interlocking, and configurable protection functions, it supports scalable feeder protection schemes and precise fault isolation in multi-feeder plants.
The unit uses semi-flush mounting, removable terminals, and has a compact footprint. Its 8.05 in depth, 8.7 in height, and 9.72 in width facilitate retrofit into existing enclosures while simplifying wiring during commissioning.
Eaton provides a one-year warranty from installation or eighteen months from shipment (whichever occurs first) under policy 25-000, with standard support for configuration and troubleshooting.