Eaton generator relay EGR-5000-2A0DB1 - PROFIBUS-DP
Part Number: EGR-5000-2A0DB1
Quick Summary
Eaton generator relay EGR-5000-2A0DB1 provides robust generator protection for industrial power systems. Engineers face challenges coordinating protective logic, avoiding nuisance trips, and maintaining uptime across diverse voltages and generator configurations. This device delivers differential protection, current and voltage protection, metering, and zone selective interlocking to optimize fault isolation. Typical certifications for generator protection relays include CE compliance, SIL safety ratings, and IP-rated enclosures when applicable; the data here shows Compliances: Contact Manufacturer, so please verify exact approvals in the official Eaton datasheet. The integration with PROFIBUS-DP communications, IRIG-B timing, and a field-proven projection mount supports fast deployment and reliable operation in demanding environments, delivering measurable business value through improved reliability and reduced maintenance overhead.
Product Information
Extended Description
EGR-5000-2A0DB1 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Profibus-DP , 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 9, Removable, Generator, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Trip Coil Monitor
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2A0DB1
UPC
786679148693
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
0
Analog outputs
0
Base relay
EGR-5000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
16
Digital outputs
9
I/O options
URTD Interface IRIG-B Trip Coil Monitor
Phase current
5A, 1A
PROFIBUS-DP
over fiber optic ST
Sensing inputs
Differential Protection Current Protection and Metering Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Eaton Specification Sheet - EGR-5000-2A0DB1
Selling Policy 25-000 - Distribution and Control Products and Services
16 digital inputs and 9 outputs provide comprehensive protection logic and flexible interfacing, enabling precise fault detection and coordinated trips across generator banks. The 2 current sensing inputs support differential protection and accurate metering, reducing nuisance trips in high-energy environments. This capability is essential for generators in data centers and manufacturing facilities where uptime is critical. The URTD Interface, IRIG-B time synchronization, and Trip Coil Monitor offer deterministic protection actions and reliable remote signaling for complex protection schemes. PROFIBUS-DP communication over fiber optic ST enables robust industrial networking, simplifying integration with plant controllers and reducing wiring costs. Removable terminals and projection mounting expedite field installation and panel maintenance, even in confined enclosures. Conformal coating enhances reliability in humid or dusty environments, while zone selective interlocking minimizes outage impact by coordinating breakers and relays across the system.
Get a Quick Quote for a Eaton EGR-5000-2A0DB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EGR-5000-2A0DB1?
Enquire Now
FAQs
The device is designed for generator protection in industrial environments and can be mounted using projection mounting with removable terminals for quick field changes. It supports up to 16 digital inputs and 9 outputs and integrates with URTD interfaces, IRIG-B time signals, and PROFIBUS-DP communications for reliable, scalable protection across generator banks and plant panels.
It provides differential protection, current protection with metering, voltage protection with metering, and power protection with metering, plus zone selective interlocking to minimize outage impact. This combination improves fault discrimination, reduces false trips, and enables coordinated reclosing sequences across multi-generator configurations in critical facilities.
The relay supports PROFIBUS-DP communications (over fiber optic ST) for robust plant networking and IRIG-B timing for precise synchronization. It also offers protective signaling via the Trip Coil Monitor and a URTD interface, enabling synchronized control and reliable data exchange with the plant control system.
The product data lists Compliances as 'Contact Manufacturer,' so exact certifications (such as CE, SIL, or IP ratings) must be confirmed in the official Eaton datasheet. When sourcing for regulated environments, always verify current approvals with Eaton to ensure alignment with your regional and industry regulatory requirements.
It carries Eaton's standard warranty policy: one year from installation or eighteen months from shipment, whichever occurs first. The unit features conformal coating for space and environmental protection, removable terminals for serviceability, and a design that facilitates quick field maintenance and replacements, supporting long-term reliability and lower total cost of ownership.