Eaton Generator Relay EGR-5000-2A0FB0 - 50/60 Hz

Part Number: EGR-5000-2A0FB0
Manufacturer
Eaton
Part number
EGR-5000-2A0FB0

Quick Summary

The Eaton generator relay protects generator sets by monitoring voltages, currents, and faults to trigger safe shutdown in industrial plants. Downtime from nuisance trips and slow fault isolation can drive maintenance costs and reduce productivity. No explicit third‑party certifications are listed; verify CE, SIL, or IP ratings with Eaton, and note the conformal‑coated boards and 1-year warranty. Optional Modbus RTU or DNP3 RTU over fiber supports SCADA integration for generator protection in modern plants. This approach helps maintenance teams align protection settings with plant-wide reliability programs while meeting performance targets. It also supports 19-300 Vdc or 40-250 Vac sensing, 50/60 Hz operation, and a removable terminal design for easier field service.

Product Information

Extended Description

EGR-5000-2A0FB0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Modbus RTU or DNP3 RTU , 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 9, Removable, Generator, 19-300Vdc, 40-250Vac, 50/60 Hz ,Trip Coil Monitor
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2A0FB0
UPC
786679149034
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
0
Analog outputs
0
Base relay
EGR-5000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
16
Digital outputs
9
I/O options
Trip Coil Monitor IRIG-B URTD Interface
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Power Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature: Flexible I/O and protection functions enable robust generator protection with 16 digital inputs, 9 outputs, and 2 current sensing inputs. Business Impact: Enables precise fault detection and selective tripping, reducing unplanned downtime and extending generator life. Application: Ideal for large facilities and data centers where reliable sequencing and interlock control are critical. The combination of high-resolution sensing and programmable outputs supports tailored protection schemes for different gensets. Feature: Communications and integration through Modbus RTU or DNP3 RTU over fiber optic ST. Business Impact: Simplifies SCADA integration, improves remote monitoring, and shortens fault diagnosis cycles. Application: Useful in centralized power plants and remote facilities seeking unified protection data streams. Feature: Wide electrical tolerance with voltage sensing inputs of 1, and power supply ranges of 19-300 Vdc or 40-250 Vac. Business Impact: Broadens compatibility with diverse generator configurations, enabling faster retrofits and lower inventory costs. Application: Retrofit projects and new builds across diverse industrial environments. Feature: Removable terminals and a semi-flush mounting method reduce installation time and ease servicing. Business Impact: Cuts commissioning labor and accelerates field maintenance windows. Application: OEM builds and preassembled switchgear where quick access matters. Feature: Conformal coated circuit boards and Trip Coil Monitor I/O options (IRIG-B URTD Interface). Business Impact: Enhances reliability in harsh environments and supports precise time synchronization for coordinated protection. Application: Industrial, outdoor, or offshore installations where environmental resilience is required.

Get a Quick Quote for a Eaton EGR-5000-2A0FB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EGR-5000-2A0FB0? Enquire Now

FAQs

Installers should use the 16 digital inputs and 9 outputs, connect the two current sensing inputs, and leverage the removable terminals for straightforward field wiring. The semi-flush mounting and 19-300 Vdc / 40-250 Vac power ranges accommodate a wide range of gensets, simplifying retrofits and new builds.
The device supports voltage protection and metering, differential protection, and power and current protection within 16 digital inputs and 9 outputs. Phase currents are available as 5A and 1A options, with one voltage sensing input, enabling precise protection coordination for generator sets.
Yes. The relay offers Modbus RTU and DNP3 RTU interfaces over fiber optic ST, allowing seamless SCADA integration, remote monitoring, and faster fault diagnosis within modern protection schemes.
Explicit third-party certifications aren’t listed in the provided data. Confirm CE, SIL, or IP ratings directly with Eaton. The unit uses conformal coated circuit boards for environmental resilience and comes with a standard one-year warranty.
Expect reduced downtime from nuisance trips due to precise protection logic and easier field service thanks to removable terminals. The 1-year warranty and flexible I/O help lower lifecycle costs, while SCADA integration via Modbus/DNP3 supports ongoing monitoring and performance optimization.