Eaton EGR-5000-2A0FB1 Generator Relay - Generator Protection
Part Number: EGR-5000-2A0FB1
Quick Summary
An Eaton generator relay is a protection device that monitors generator parameters and trips to prevent faults and outages in critical power systems. This model supports versatile communications and wide input ranges, helping engineers simplify protection schemes and reduce deployment time. While many Eaton generator protection relays are built to meet demanding industry needs, verify the exact approvals from the manufacturer to ensure compliance for your site. In practice, customers rely on robust features like Modbus RTU and DNP3 RTU over fiber, removable terminals, and conformal coated boards to enhance reliability in harsh environments. This product also supports remote monitoring and metering workflows, improving asset visibility and operational efficiency across distributed genset fleets.
Product Information
Extended Description
EGR-5000-2A0FB1 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Modbus RTU or DNP3 RTU , 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 9, Removable, Generator, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2A0FB1
UPC
786679149140
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
0
Analog outputs
0
Base relay
EGR-5000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
16
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Differential Protection Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: 16 digital inputs and 9 digital outputs enable complex protection and control logic, reducing manual intervention and enabling automated trip schemes for standby generators in data centers or industrial plants. This translates to improved system availability and faster fault isolation when paired with zone selective interlocking and trip coil monitoring. Feature → Application: Power supply range of 19-300 VDC or 40-250 VAC supports varied site power architectures, simplifying installation and reducing the need for multiple adapters. Business impact: lower wiring costs and faster commissioning across new genset installations. Feature → Application: Modbus RTU or DNP3 RTU over fiber ST provides secure, long-distance communication with SCADA, enabling centralized monitoring and predictive maintenance. Business impact: enhanced asset health insights and reduced MTTR. Feature → Application: 50/60 Hz compatibility and projection mounting deliver dependable mechanical integration in switchgear rooms and outdoor enclosures, minimizing space and mounting complexity. Business impact: scalable deployment and quicker retrofit of legacy protection schemes. Feature → Application: Removable terminals and conformal coated circuit boards enhance serviceability and reliability in challenging environments, reducing downtime during maintenance. Business impact: easier field upgrades and extended product life. Feature → Application: IRIG-B Trip Coil Monitor and multiple I/O options expand compatibility with existing protection architectures, supporting seamless integration with legacy protection philosophies while enabling modern, modular upgrades.
Get a Quick Quote for a Eaton EGR-5000-2A0FB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EGR-5000-2A0FB1?
Enquire Now
FAQs
The relay features projection mounting with removable terminals, simplifying installation and field upgrades. It supports 16 digital inputs and 9 outputs, enabling compact protection schemes without extra canvassing of cabinet space.
Communication is provided over fiber optic ST, allowing secure, long-distance data exchange with SCADA or EMS systems. This enables centralized monitoring, firmware updates, and remote diagnostics for generators in distributed assets.
Yes. With 50/60 Hz support, programmable protection logic, and zone selective interlocking, it provides fast fault isolation and reliable generator protection in critical facilities like data centers.
Compliances are listed as Contact Manufacturer; verify exact approvals and certifications in the Eaton datasheet or through a representative to ensure site-specific regulatory compliance.
Benefits include reduced MTTR due to faster fault detection, lower wiring and commissioning costs thanks to flexible power ranges and removable terminals, and improved asset health monitoring via Modbus/DNP3 connectivity, all contributing to lower total cost of ownership.