Eaton EGR-5000-2A0HA0 Generator Protection Relay - IEC 61850
Part Number: EGR-5000-2A0HA0
Quick Summary
Eaton generator relay protects and monitors standby and prime power generators across industrial facilities. Operators often struggle with unreliable protection coordination and lack of real-time visibility during faults or startup. Compliance considerations vary by region; many Eaton relays support CE marking and rugged IP-rated housings suitable for harsh environments. By integrating IEC 61850, DNP3 TCP/UDP over Ethernet, and Ethernet connectivity, this relay enables scalable protection schemes and faster fault isolation. This combination reduces downtime, improves coordination with upstream breakers, and simplifies field maintenance for engineers and procurement teams.
Product Information
Extended Description
EGR-5000-2A0HA0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 9,Generator, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2A0HA0
UPC
786679153710
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
0
Analog outputs
0
Base relay
EGR-5000
Conformal coating
None
Current sensing inputs
2
Digital inputs
16
Digital outputs
9
I/O options
Trip Coil Monitor IRIG-B URTD Interface
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Voltage Protection and Metering Power Protection and Metering Differential Protection
Zone selective interlocking
1
Number of inputs
16
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature: IEC 61850, DNP3 TCP/UDP over Ethernet and URTD Interface enable seamless interoperability. Business Impact: Faster integration with modern protection schemes reduces engineering time and supports centralized monitoring. Application: Data centers and utilities deploying Ethernet-based protection architectures. The application benefits from standardized communication and remote diagnostics. Feature: 16 digital inputs, 9 digital outputs, 2 current sensing inputs and 5A/1A phase current options. Business Impact: Rich I/O enables comprehensive protection logic and precise tripping coordination, lowering fault cascades. Application: Generator protection coordinating with upstream breakers in large plants. Feature: Power supply range 19-300 Vdc and 40-250 Vac with 50/60 Hz. Business Impact: Flexible installation across diverse plant electrical environments, simplifying retrofits. Application: Retrofit projects and new builds with mixed supply schemes. Feature: I/O options including Trip Coil Monitor, IRIG-B, and URTD Interface. Business Impact: Enhanced monitoring and time synchronization improve fault analysis and post-event review. Application: Utility-scale generators requiring accurate time stamping. Feature: Semi-flush mounting and removable terminals. Business Impact: Easier field installation and maintenance, reducing commissioning time and wiring errors. Application: Rack or panel installations in constrained plant spaces. Feature: Zone selective interlocking with 1 indication. Business Impact: Improved selective tripping reduces outage impact and improves system reliability. Application: Protective coordination in multi-bus facilities. Feature: Warranty and support through Eaton policies. Business Impact: Lower total cost of ownership and clear service expectations. Application: Long-term asset protection with predictable service windows.
Get a Quick Quote for a Eaton EGR-5000-2A0HA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EGR-5000-2A0HA0?
Enquire Now
FAQs
Install the relay on a suitable enclosure using the semi-flush mounting method and ensure Removable Terminals are accessible for wiring. Use the 16 digital inputs and 9 digital outputs to configure protective logic, wire current sensing inputs to the generator CTs, and connect the Ethernet interface for IEC 61850 or DNP3 communication to your SCADA system.
The unit supports IEC 61850 and DNP3 TCP/UDP over Ethernet for protection and monitoring. Configuration is performed via the built-in interface or engineering software, mapping digital I/Os, setting zone selective interlocking, and enabling the required metering and protection functions (current, voltage, power, differential protections) to align with your protection philosophy.
Yes. Its multi-protocol Ethernet communications, flexible I/O, and comprehensive metering provide robust protection coordination for critical loads. The 50/60 Hz compatibility and wide power-supply range support both standby and prime generator configurations typical in data centers and utility-grade facilities.
Compliance status is region and configuration dependent. Our data indicates manufacturer-directed compliance; verify CE marking, IP enclosure rating, and any SIL requirements directly with Eaton for your installation site to ensure regulatory alignment and safety certifications.
The EGR-5000-2A0HA0 consolidates protection and monitoring functions, reducing downtime through faster fault isolation and improved coordination. Its removable terminals and semi-flush mounting simplify commissioning and routine maintenance, lowering labor costs and accelerating field servicing while supporting scalable protection schemes.