Eaton EGR-5000-2A0LA1 Generator Relay - 50/60 Hz
Part Number: EGR-5000-2A0LA1
Quick Summary
Eaton generator relay EGR-5000-2A0LA1 provides reliable generator protection for energy systems. Engineers often struggle with integrating multiple sensing channels, voltages, and remote monitoring into a single protective solution, which can complicate commissioning and maintenance. Compliances vary by region, so confirm regional certifications with Eaton and review warranty terms early in the project. In practice, this device offers 16 digital inputs and 9 outputs, dual power options (19-300 Vdc or 40-250 Vac), and flexible communication capabilities to support scalable protection schemes and streamlined maintenance across facilities.
Product Information
Extended Description
EGR-5000-2A0LA1 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 9,Generator, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2A0LA1
UPC
786679150016
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
0
Analog outputs
0
Base relay
EGR-5000
Conformal coating
None
Current sensing inputs
2
Digital inputs
16
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Current Protection and Metering Power Protection and Metering Differential Protection
Zone selective interlocking
1
Number of inputs
16
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Feature: 16 digital inputs and 9 outputs enable complex protection logic and seamless control; Business Impact: simplifies wiring, reduces panel space, and supports advanced protection schemes like zone selective interlocking; Application: generator protection for industrial plants and data centers. Feature: 2 current sensing inputs plus 5A/1A phase currents enable accurate, configurable protection without external sensors; Business Impact: improves fault discrimination and reduces nuisance trips; Application: varied generator configurations with precise metering. Feature: Wide power supply range 19-300 Vdc and 40-250 Vac; Business Impact: enables single-model deployment across sites with different power architectures; Application: retrofits and scalable protection for multi-site operations. Feature: Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet with IRIG-B Trip Coil Monitor URTD Interface; Business Impact: simplifies remote monitoring, SCADA integration, and fast fault localization; Application: modern industrial networks and utilities. Feature: Projection mounting with removable terminals; Business Impact: eases installation and field wiring, reduces commissioning time; Application: rugged, field-serviceable protection relays in harsh environments. Feature: Zone selective interlocking and differential protection capabilities; Business Impact: minimizes outage impact and improves selective tripping; Application: critical generator banks and backup power infrastructures.
Get a Quick Quote for a Eaton EGR-5000-2A0LA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EGR-5000-2A0LA1?
Enquire Now
FAQs
The EGR-5000-2A0LA1 is designed for generator protection in industrial plants, data centers, and backup power applications. It provides 16 digital inputs, 9 outputs, and 2 current sensing inputs, with projection mounting and removable terminals to simplify field wiring and installation across a range of site configurations.
Key specs include 19-300 Vdc or 40-250 Vac power supply, 50/60 Hz operation, 16 digital inputs, 9 outputs, 2 current sensing inputs, and phase current ratings of 5A and 1A. It supports Mbus TCP or DNP3 TCP/UDP communications over Enet, along with IRIG-B Trip Coil Monitor URTD interface for remote monitoring and protection.
Yes. The EGR-5000-2A0LA1 provides Zone Selective Interlocking with one zone and supports differential protection, enabling selective tripping to minimize outage impact while maintaining robust protection for generator banks.
Installation benefits include projection mounting and removable terminals for easier wiring and servicing. Warranty follows Eaton policy 25-000: one year from installation or eighteen months from shipment, whichever comes first, with regional variations to be confirmed with the manufacturer.
The relay supports Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, enabling SCADA integration and remote monitoring. It also offers an IRIG-B Trip Coil Monitor URTD interface, voltage/current/protection metering, and compatibility with URTD and other networked protection schemes for centralized management.