Eaton Generator Relay EGR-5000-2A1DB0 - Profibus-DP over fiber

Part Number: EGR-5000-2A1DB0
Manufacturer
Eaton
Part number
EGR-5000-2A1DB0

Quick Summary

The generator relay is a powerful protection device that safeguards generator sets and supports reliable operation in industrial plants. It provides robust fault detection and coordinated protection without unnecessary wiring complexity, helping maintain uptime and reduce maintenance cycles. Certification details vary by region; confirm CE and UL listings and, where applicable, IP ratings with Eaton. This device features Profibus-DP over fiber and a conformally coated PCB, delivering network-ready protection in harsh environments. With removable terminals and 16 digital inputs feeding into 9 outputs, it enables scalable protection schemes across mixed-generation assets and evolving control architectures. For project teams, this translates into quicker commissioning, easier field service, and improved overall protection performance and reliability.

Product Information

Extended Description

EGR-5000-2A1DB0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Profibus-DP , 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 9, Removable, Generator, 19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil MonitorSensitive Ground Input,
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2A1DB0
UPC
786679150320
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
0
Analog outputs
0
Base relay
EGR-5000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
16
Digital outputs
9
I/O options
Sensitive Ground Input Trip Coil Monitor URTD Interface IRIG-B
Phase current
5A, 1A
PROFIBUS-DP
over fiber optic ST
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Differential Protection Current Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
16 digital inputs enable rich signal collection for protection logic, delivering faster fault recognition and more precise trip decisions; the business impact is reduced unplanned downtime and tighter protective coordination in generator banks. This directly supports applications in power plants and critical facilities where uptime is paramount and miscoordination can be costly. The 9 configurable outputs provide direct interlocks and alarm controls, reducing external wiring and enabling compact enclosure designs while maintaining clear fault annunciation for operators. In practice, this means easier panel wiring, faster commissioning, and lower maintenance overhead during lifecycle operations. The power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz compatibility offers global install flexibility, minimizing regional variants and simplifying spare-part strategies. This translates to lower total cost of ownership and faster ROI for multi-site deployments. Removable terminals and semi-flush mounting simplify service and upgrades, enabling technicians to diagnose and rewire quickly without full system downtime. The conformal coating on circuit boards improves reliability in humid, dusty, or vibration-prone environments, reducing corrosion risk and extending field life. I/O options like Sensitive Ground Input, Trip Coil Monitor, URTD Interface, and IRIG-B timing expand diagnostic capabilities and timing precision, supporting advanced protection schemes and easier integration with legacy control networks. PROFIBUS-DP over fiber optic ST provides robust, noise-immune communication to PLCs and SCADA systems, ensuring reliable data transfer in electrically noisy plants. Zone selective interlocking (1) enables coordinated, selective tripping to minimize outages and improve system selectivity in large generator arrangements.

Get a Quick Quote for a Eaton EGR-5000-2A1DB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EGR-5000-2A1DB0? Enquire Now

FAQs

Installations should accommodate semi-flush mounting and the removable terminals for fast wiring and future service. Plan for enclosure depth and clearances, ensure proper grounding, and verify the 16 digital inputs and 9 outputs align with your protection logic. Use shielded cables where applicable and route PROFIBUS-DP fiber connections away from high-power conductors to minimize interference.
The relay supports power inputs of 19-300 Vdc and 40-250 Vac, with a nominal frequency of 50/60 Hz. It provides 16 digital inputs and 9 outputs, two current-sensing inputs, and voltage protection/metering, power protection/metering, differential protection, and current protection/metering sensing modes. It also offers Profibus-DP communication over fiber optic ST, enabling network integration.
Yes. The unit includes PROFIBUS-DP communication over a fiber optic ST interface, allowing reliable, noise-immune data exchange with PLCs and SCADA systems. This makes it suitable for integrated protection schemes in plants using industrial Ethernet/fieldbus networks, with easy integration into existing control architectures.
The EGR-5000-2A1DB0 is covered by Eaton's standard warranty: 1 year from installation or 18 months from shipment, whichever comes first. For service and spare parts, contact Eaton or your authorized distributor. Warranty terms may vary by region, so regional confirmation is recommended before deployment.
By consolidating protection inputs and controls into a single generator relay with removable terminals and conformal-coated boards, maintenance becomes faster and less disruptive. The networked Profibus-DP interface reduces wiring complexity, while zone selective interlocking and integrated metering support faster fault isolation, lowering downtime costs and improving overall equipment availability.