Eaton EGR-5000-2A1LA0 Generator Relay - 50/60 Hz
Part Number: EGR-5000-2A1LA0
Quick Summary
Eaton generator relay EGR-5000-2A1LA0 is a generator protection relay designed to safeguard power systems in industrial facilities. Customers often struggle with reliable protection, fast fault reporting, and seamless integration with SCADA across diverse networks. Compliances are provided by the manufacturer; for exact coverage, confirm CE marking, SIL readiness, and IP-related ratings with Eaton. This solution integrates with Mbus TCP or DNP3 TCP/UDP over LC fiber Ethernet, enabling scalable monitoring and remote diagnostics. By combining broad I/O and flexible power sourcing with easy installation, it reduces downtime and total cost of ownership for generator protection schemes.
Product Information
Extended Description
EGR-5000-2A1LA0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 9,Generator, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil MonitorSensitive Ground Input,
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2A1LA0
UPC
786679153635
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
0
Analog outputs
0
Base relay
EGR-5000
Conformal coating
None
Current sensing inputs
2
Digital inputs
16
Digital outputs
9
I/O options
Trip Coil Monitor IRIG-B URTD Interface Sensitive Ground Input
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Current Protection and Metering Voltage Protection and Metering Differential Protection
Zone selective interlocking
1
Number of inputs
16
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
16 digital inputs, 9 outputs, and 2 current-sensing inputs enable comprehensive protection logic and local control without external modules. This consolidation reduces panel wiring complexity and lowers installation risk, making it well suited for generator protection in data centers, manufacturing facilities, and critical infrastructure. The device supports Mbus TCP and DNP3 TCP/UDP over LC duplex fiber Ethernet, enabling seamless SCADA integration, remote diagnostics, and faster fault resolution in industrial environments. With a power-supply range of 19-300 Vdc or 40-250 Vac and a 50/60 Hz rating, it delivers flexible installation across diverse plant electrical systems, improving overall reliability and reducing site-digitization efforts. Zone selective interlocking and differential protection capabilities translate to targeted tripping and reduced outage impact, supporting uptime metrics in mission-critical operations. The base EGR-5000 platform, removable terminals, and semi-flush mounting simplify field wiring and panel layout, cutting commissioning time and service costs. I/O options such as Trip Coil Monitor, IRIG-B, URTD Interface, and Sensitive Ground Input extend protection coverage for complex generator banks and multi-panel installations, ensuring scalable system growth without replacement.
Get a Quick Quote for a Eaton EGR-5000-2A1LA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EGR-5000-2A1LA0?
Enquire Now
FAQs
The EGR-5000-2A1LA0 uses removable terminals and a semi-flush mounting method, which simplifies wiring and mounting in existing panels. With 16 digital inputs and 9 outputs, it consolidates protection functions in a single device, reducing cabling and panel footprint while preserving compatibility with common panel layouts.
Key features include 1) 2 current-sensing inputs for accurate protection logic, 2) zone selective interlocking for targeted trips, and 3) differential protection alignment. Together these reduce unintended outages and improve selectivity, essential for banks of generators in data centers and critical facilities.
It supports Mbus TCP and DNP3 TCP/UDP over LC duplex fiber Enet, enabling robust communication with SCADA systems and remote diagnostics. This integration reduces MTTR, enables faster fault localization, and supports centralized asset management across distributed sites.
Compliances are provided by the manufacturer; verify CE marking, SIL readiness, and IP-related ratings with Eaton for your installation. Always confirm the exact certifications applicable to your jurisdiction and project scope with the vendor prior to procurement.
ROI is driven by reduced unplanned outages, faster fault isolation, and lower commissioning complexity. The device’s integrated I/O, flexible power range, and SCADA-ready communications minimize wiring, testing time, and service visits, delivering measurable uptime gains and lower total cost of ownership in high-demand environments.