Eaton generator relay EGR-5000-2A1LB0 - Mbus TCP / DNP3 Enet

Part Number: EGR-5000-2A1LB0
Manufacturer
Eaton
Part number
EGR-5000-2A1LB0

Quick Summary

Eaton generator relay protects industrial generators during startup and operation. This device is designed to prevent faults from escalating into outages, helping you maintain uptime in mission-critical power systems. While many protection relays require complex configuration, the EGR-5000-2A1LB0 simplifies integration with its 16 digital inputs, 9 outputs, and 2 current sensing inputs, all within a wide power range. Compliances are specified by the manufacturer; reviewers typically look for CE and UL listings and enclosure IP ratings depending on installation. For procurement and installation teams, this translates to faster commissioning and reduced risk, while electrical professionals benefit from robust, field-proven protection with Ethernet-enabled monitoring and flexible I/O options.

Product Information

Extended Description

EGR-5000-2A1LB0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 9,Generator, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,Sensitive Ground Input
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2A1LB0
UPC
786679148624
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
0
Analog outputs
0
Base relay
EGR-5000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
16
Digital outputs
9
I/O options
Trip Coil Monitor Sensitive Ground Input IRIG-B URTD Interface
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Power Protection and Metering Differential Protection Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: 16 digital inputs and 9 digital outputs enable comprehensive protection logic and interlocking across generator, bus, and switching configurations, reducing false trips and enabling precise control in complex switchgear. This translates to measurable downtime reduction and improved system reliability in data centers, manufacturing lines, and critical facilities. Feature → Application → Benefit: Wide power supply range of 19–300 Vdc and 40–250 Vac supports diverse power sources and transition scenarios, simplifying installation in mixed fleet environments and minimizing equipment staging costs. Feature → Application → Benefit: Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet delivers modern, scalable remote monitoring and integration with SCADA systems, boosting visibility and enabling predictive maintenance. Feature → Application → Benefit: 5A, 1A phase current sensing and 2 current sensing inputs provide accurate protection coordination and metering, improving fault diagnostics and energy management. Feature → Application → Benefit: 16 inputs, 9 outputs, and 1-zone select interlock support sophisticated protection schemes with minimal wiring complexity, reducing engineering time and cabinet footprint. Feature → Application → Benefit: Removable terminals and semi-flush mounting simplify field wiring and service, accelerating installation and future upgrades. Feature → Application → Benefit: Conformal coated circuit boards enhance reliability in harsh environments, lowering maintenance costs and extending mean time between failures. Feature → Application → Benefit: Trip Coil Monitor and Sensitive Ground Input add redundancy for critical protection paths, reducing the risk of undetected faults in generator protection. Feature → Application → Benefit: IRIG-B URTD Interface provides time synchronization options for power system protection schemes, enabling precise event correlation in large installations. These combined capabilities support faster commissioning, lower total cost of ownership, and stronger compliance with industrial protection standards.

Get a Quick Quote for a Eaton EGR-5000-2A1LB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EGR-5000-2A1LB0? Enquire Now

FAQs

Yes. The EGR-5000-2A1LB0 features removable terminals and semi-flush mounting, 16 digital inputs and 9 outputs, and a wide power supply range (19-300 Vdc, 40-250 Vac). This makes it straightforward to retrofit into current power cabinets and synchronize with existing protection schemes, minimizing cabinet rework and wiring labor.
It offers generator protection with multiple sensing inputs (2 current sensing inputs, 16 DI, 9 DO), Trip Coil Monitor, and a Sensitive Ground Input option. The device supports Mbus TCP or DNP3 TCP/UDP over Enet, enabling remote supervision and fast fault indication, reducing response times and improving reliability in critical applications.
Yes. Its wide input range, robust protection logic, and Ethernet-enabled communications align well with data center needs for uptime and visibility. The 50/60 Hz compatibility, along with configurable protection and metering, supports seamless integration with data center monitoring and automated maintenance routines.
The manufacturer specifies compliance details separately; the listing shows 'Compliances: Contact Manufacturer'. In practice, users typically verify CE, UL/ULc, and IP ratings through Eaton’s documentation for the final installation, ensuring alignment with regional electrical standards and enclosure protection requirements.
By providing precise protection coordination, reduced false trips, and Ethernet-based monitoring, this relay helps minimize unplanned outages and enables predictive maintenance. Its conformal coating and robust physical design lower maintenance costs, while faster commissioning and easier upgrades cut engineering effort and downtime during expansion or relocation.