Eaton Generator Relay EGR-5000-2B0EB1 - 50/60 Hz

Part Number: EGR-5000-2B0EB1
Manufacturer
Eaton
Part number
EGR-5000-2B0EB1

Quick Summary

Eaton Generator Relay protects generators by monitoring protection inputs and controlling trips in standby power systems. Engineers often battle nuisance trips and slow response under fluctuating loads, risking unplanned outages. Certification details are not listed in the data; consult Eaton for CE, SIL, or IP ratings applicable to your region. The device supports PROFIBUS-DP over D-Sub/RS-485, a wide supply range (19-300 Vdc, 40-250 Vac), and robust IO with 8 digital inputs and 9 outputs, enabling scalable protection schemes. This combination reduces downtime, simplifies commissioning, and helps align generator protection with plant-wide automation standards, delivering measurable uptime and reliability.

Product Information

Extended Description

EGR-5000-2B0EB1 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Generator, over D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor,
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2B0EB1
UPC
786679149638
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
2
Analog outputs
2
Base relay
EGR-5000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Current Protection and Metering Differential Protection Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Feature: Flexible power supply and wide I/O. Business Impact: Simplifies installation across locations with varying power architectures, reducing cabling and commissioning time. Application: Ideal for retrofit projects and new builds where 19-300 Vdc and 40-250 Vac ranges are present. Feature: Extensive I/O and sensing. Business Impact: Enables complex protection schemes with precise metering and fast response; reduces nuisance trips. Application: Suitable for generator protection in power plants and data centers. Feature: PROFIBUS-DP over D-Sub / RS-485. Business Impact: Enables seamless plant-network integration and remote diagnostics. Application: Connects to central PLCs in industrial environments. Feature: I/O options including IRIG-B Trip Coil Monitor and URTD Interface. Business Impact: Provides time synchronization and additional monitoring for secure trip coordination. Application: Critical generator protection in mission-critical facilities. Feature: Robust mechanical design with conformal coating and removable terminals. Business Impact: Improves reliability in harsh environments and streamlines field installation. Application: Industrial installations with space and environmental constraints.

Get a Quick Quote for a Eaton EGR-5000-2B0EB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EGR-5000-2B0EB1? Enquire Now

FAQs

Begin by locating a clean, ventilated enclosure near the generator. Mount the unit in Projection mode and connect the removable terminals to the generator sensing and control circuits. Wire digital inputs and outputs (8 DI, 9 DO), along with the 2 analog inputs/2 analog outputs for metering. Verify PROFIBUS-DP over D-Sub/RS-485 networking for PLC communication and power the unit within 19-300 Vdc or 40-250 Vac. Finally, perform a functional test to confirm proper trip coordination and network visibility.
Key specs include a dual power supply range of 19-300 Vdc and 40-250 Vac, 50/60 Hz operation, 8 digital inputs, 9 digital outputs, and 2 analog inputs with 2 analog outputs. The PROFIBUS-DP interface operates over D-Sub or RS-485, enabling integration with existing control networks. Sensing inputs include current protection, differential protection, voltage protection, and power metering for comprehensive generator protection.
Yes. The EGR-5000-2B0EB1 is designed for generator protection with zone selective interlocking and wide input ranges, suitable for standby power in manufacturing. Its IRIG-B Trip Coil Monitor and URTD interface support precise trip coordination, while the 8/9 IO set enables robust protective schemes. Ensure integration with your plant’s automation network via PROFIBUS-DP for remote monitoring and diagnostics.
Compliances are listed as Contact Manufacturer, so check with Eaton for the exact CE, UL, IP, or SIL certifications applicable to your region and installation. When planning procurement, confirm these certifications align with local electrical codes and industry standards before installation to ensure regulatory approval and safe operation.
The device includes conformal coating on circuit boards and removable terminals, which reduces maintenance downtime in harsh environments. A one-year warranty (or 18 months from shipment) provides initial protection, and the firmware-compatible design supports long-term ROI by minimizing nuisance trips and enabling scalable protection as plant needs grow. Regular diagnostics via PROFIBUS-DP help prevent unexpected outages.