Eaton EGR-5000-2B0GB0 Generator Relay - Conformal Coated
Part Number: EGR-5000-2B0GB0
Quick Summary
Eaton generator relay protects generators by monitoring critical parameters in power systems. This device is designed to coordinate protection schemes, reduce unintended trips, and support reliable generator control in industrial facilities. Certification and compliance specifics for this model should be confirmed with Eaton; generator protection relays in this class typically reference CE/UL marks and regional IP considerations depending on installation. With wide power-supply ranges and flexible communications, it supports modern automation goals for reliable uptime, seamless SCADA integration, and scalable protection across multiple genset configurations.
Product Information
Extended Description
EGR-5000-2B0GB0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Generator, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil Monitor,
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2B0GB0
UPC
786679149904
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
2
Analog outputs
2
Base relay
EGR-5000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Differential Protection Current Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Eaton Specification Sheet - EGR-5000-2B0GB0
Selling Policy 25-000 - Distribution and Control Products and Services
Feature: Wide power supply range of 19-300 VDC and 40-250 VAC, plus 50/60 Hz operation. Business Impact: Enables global deployments with a single platform, reducing part variety and stocking costs. Application: Ideal for mixed-voltage genset ecosystems in international facilities. The Eaton EGR-5000-2B0GB0 maintains consistent protection logic across diverse power sources, simplifying installation and maintenance. Feature: Eight digital inputs and nine outputs with two analog inputs and two analog outputs. Business Impact: Flexible I/O facilitates precise trip coordination, monitoring, and metering, improving protection selectivity and reducing nuisance trips. Application: Generator protection relay in medium-sized power plants and critical facilities. Feature: Modbus RTU or DNP3 RTU over D-Sub RS-485. Business Impact: Seamless SCADA integration and remote diagnostics, lowering operational costs and downtime. Application: Remote control rooms and plant-wide protection schemes. Feature: Removable terminals and conformal coating. Business Impact: Easier wiring, faster service, and enhanced reliability in harsh environments. Application: Field installations subject to vibration, humidity, or dust. Feature: I/O options including IRIG-B Trip Coil Monitor URTD Interface. Business Impact: Advanced time synchronization and monitoring support for interlocked protection sequences. Application: Utility-scale and data-center generator configurations. Feature: Phase current options of 5A and 1A, with power/sensing inputs for comprehensive protection schemes. Business Impact: Accurate current sensing improves protection accuracy and reduces mistrips. Application: Differential and overcurrent protection scenarios. Feature: Zone selective interlocking (ZSI) with 1 channel. Business Impact: minimizes outage impact by fast-tracking protection within a zone, improving reliability. Application: Coordinated feeder protection in complex generator arrays. Feature: Conformal coated circuit boards. Business Impact: Enhanced reliability in humid or dusty environments, reducing maintenance cycles. Application: Outdoor or service-indoor installations with harsh conditions.
Get a Quick Quote for a Eaton EGR-5000-2B0GB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EGR-5000-2B0GB0?
Enquire Now
FAQs
Begin with confirming the 19-300 VDC or 40-250 VAC supply, then mount the unit using the semi-flush mounting method. Use the removable terminals to streamline wiring, connect 8 digital inputs, 9 outputs, and the 2 analog channels, and wire the RS-485 Modbus/DNP3 RTU for SCADA communication. Follow the manufacturer’s guidelines for grounding and protective enclosure integrity to ensure optimal protection performance.
The relay supports Modbus RTU or DNP3 RTU over D-Sub RS-485, enabling robust integration with SCADA systems and remote monitoring. It also offers flexible I/O options including IRIG-B and Trip Coil Monitor interfaces to support time synchronization and protective interlocks in complex generator configurations.
Yes. The unit features conformal coated circuit boards and removable terminals for ease of maintenance, plus a wide operating power range that accommodates varied supply configurations. For installations in harsh environments, the coating helps resist humidity and contaminants, while the removable terminals simplify field wiring and service access.
The product follows Eaton's selling policy SP 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. For ongoing support, consult Eaton’s technical resources and partner network to obtain service, replacement parts, and firmware updates as needed.
Its broad input/output capabilities (8 inputs, 9 outputs, 2 analog in/out), wide voltage range, and RS-485 communications enable precise protection coordination and easier integration with existing SCADA systems. Features like removable terminals and conformal coating reduce install time and maintenance costs while improving reliability and uptime, delivering faster payback through reduced downtime.