Eaton EGR-5000-2B0HA0 Generator Relay - 61850/Mbus/DNP3 TCP

Part Number: EGR-5000-2B0HA0
Manufacturer
Eaton
Part number
EGR-5000-2B0HA0

Quick Summary

Eaton generator relay EGR-5000-2B0HA0 delivers robust generator protection for industrial power systems. This relay defines fault conditions clearly and coordinates protective actions across generators and remote sites, reducing unplanned outages. It supports IEC 61850, DNP3 TCP/UDP, and M-Bus TCP over Ethernet, enabling seamless integration with modern protection schemes. The unit features flexible IO—8 digital inputs, 9 digital outputs, 2 analog inputs, 2 analog outputs, and 2 current sensing inputs—plus URTD and Trip Coil Monitor options to adapt to evolving protection needs. Semi-flush mounting, removable terminals, and IRIG-B compatibility simplify installation and maintenance, driving faster commissioning and lower lifecycle costs. In short, it empowers engineers to meet reliability targets while protecting valuable generator assets.

Product Information

Extended Description

EGR-5000-2B0HA0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Generator, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2B0HA0
UPC
786679152911
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
2
Analog outputs
2
Base relay
EGR-5000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Current Protection and Metering Differential Protection Power Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature: Flexible protection IO and I/O options. Benefit: Consolidates generator protection with scalable input/output, reducing wiring complexity and cabinet footprint. Application: Ideal for multi-generator sites requiring coordinated protection strategies. Long-tail keywords: generator protection relay IO, URTD interface, Trip Coil Monitor, IRIG-B compatibility. Feature: Communications and interoperability. Benefit: Enables seamless integration with modern protection schemes via IEC 61850, DNP3 TCP/UDP, M-Bus TCP over Ethernet RJ45. Application: Data centers and plants with mixed vendor protection networks. Long-tail keywords: Ethernet-based protection relay, IEC 61850 protocol, DNP3 TCP/UDP support. Feature: Power and electrical flexibility. Benefit: Supports wide supply ranges (19-300 Vdc, 40-250 Vac) and 50/60 Hz operation, enabling use with diverse gensets. Application: Retrofit and new builds across different regions. Long-tail keywords: 50/60 Hz generator protection, wide power supply range. Feature: Time synchronization and monitoring options. Benefit: URTD, IRIG-B, and Trip Coil Monitor improve fault timing accuracy and coordination, reducing miscoordination risk. Application: Critical infrastructure protection where precise time stamping matters. Long-tail keywords: IRIG-B time sync, Trip Coil Monitor. Feature: Installation efficiency and serviceability. Benefit: Semi-flush mounting and removable terminals speed installation and maintenance, lowering labor costs. Application: Field deployments and retrofit projects. Long-tail keywords: semi-flush mounting, removable terminals, installation efficiency. Feature: Coordination and reliability features. Benefit: Zone selective interlocking supports fast, selective tripping, minimizing outages and improving system reliability. Application: Utility-scale and industrial plants requiring selective protection. Long-tail keywords: zone selective interlocking, protection coordination. Warranty and support: One-year warranty from installation or 18 months from shipment, aiding total cost of ownership.

Get a Quick Quote for a Eaton EGR-5000-2B0HA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EGR-5000-2B0HA0? Enquire Now

FAQs

Yes. The EGR-5000-2B0HA0 uses the EGR-5000 base family and is designed for semi-flush mounting with removable terminals, simplifying wiring and field service. It also supports URTD interfaces, Trip Coil Monitor, and IRIG-B time synchronization for flexible installation across generator rooms.
The relay natively supports IEC 61850, DNP3 TCP/UDP, and M-Bus TCP over Ethernet RJ45, enabling seamless cross-vendor integration and easy remote monitoring. This interoperability reduces engineering effort during integration and improves fault visibility across protection networks.
Yes. Designed as a generator protection relay, it handles 50/60 Hz operation, wide power-supply ranges, and extensive IO for protection and metering, making it suitable for data centers, industrial plants, and utility-scale installations requiring coordinated protection and reliable monitoring.
The provided data lists compliance as 'Contact Manufacturer,' so specific certifications (SIL, CE, IP, etc.) are not disclosed here. For formal certification status, consult Eaton's compliance documentation or technical support to confirm current certifications for your region and application.
The device offers a one-year warranty from installation (or 18 months from shipment) and features like IRIG-B time synchronization, Trip Coil Monitor, and zone selective interlocking, which together reduce downtime and maintenance costs by improving fault timing, coordination, and serviceability.