Eaton EGR-5000-2B0HB0 Generator Relay - Conformal Coated

Part Number: EGR-5000-2B0HB0
Manufacturer
Eaton
Part number
EGR-5000-2B0HB0

Quick Summary

Eaton generator relay EGR-5000-2B0HB0 protects generators by delivering fast protection and monitoring over Ethernet for industrial power systems. This device helps eliminate protection miscoordination and false trips in multi-generator environments with mixed communications. Certification details are provided by Eaton and should be verified for your site, including CE, SIL readiness, and IP ratings applicable to this model. With a 50/60 Hz operation and a wide input range (19–300 VDC and 40–250 VAC), the EGR-5000-2B0HB0 supports diverse generator sets and installation configurations. The 8 digital inputs, 9 outputs, and dual analog channels streamline wiring, monitoring, and metering, enabling faster commissioning and predictable uptime while reducing total cost of ownership.

Product Information

Extended Description

EGR-5000-2B0HB0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Generator, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz ,Trip Coil Monitor
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2B0HB0
UPC
786679153475
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
2
Analog outputs
2
Base relay
EGR-5000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature: 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45 for protection communication. Business Impact: Enables seamless integration with modern protection schemes, reducing engineering time and miscommunication across control rooms. Application: Ideal for generator protection in plants, data centers, and utilities. Feature: Wide power supply range of 19-300 VDC and 40-250 VAC with 50/60 Hz. Business Impact: Simplifies cabinet design and spare-part planning by supporting diverse generator sets. Application: Installation on mixed-voltage generator fleets without extra adapters. Feature: Eight digital inputs, nine outputs, two analog inputs and two analog outputs. Business Impact: Delivers rich data for monitoring and control, enabling advanced protection logic and remote signaling. Application: Local control panels and remote alarming in industrial sites. Feature: I/O options including URTD Interface, Trip Coil Monitor, and IRIG-B. Business Impact: Time-synchronised data and expanded failure monitoring reduce unplanned downtime. Application: Fleet-wide protection schemes requiring precise timing and trip verification. Feature: Phase current sensing with 5A/1A options and multiple protection profiles (Current, Differential, Power, Voltage). Business Impact: Improves selectivity, fast fault isolation, and reduced outage impact. Application: High-availability gensets in data centers and manufacturing lines. Feature: Conformal coated circuit boards and removable terminals with semi-flush mounting. Business Impact: Enhanced reliability in harsh environments and simpler routine maintenance. Application: Outdoor or humid plant areas where wiring longevity matters.

Get a Quick Quote for a Eaton EGR-5000-2B0HB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EGR-5000-2B0HB0? Enquire Now

FAQs

Installation steps start with confirming the power supply within 19-300 VDC or 40-250 VAC and 50/60 Hz. Use the removable terminals for clean wiring and the semi-flush mounting option for a tidy panel installation. Connect the eight digital inputs, nine outputs, and the two analog channels as per the protection scheme, and integrate the URTD interface, IRIG-B, and Trip Coil Monitor for time-synchronized control.
Key specs include eight digital inputs, nine outputs, two analog inputs and two analog outputs, plus phase current sensing of 5A/1A. It supports 50/60 Hz operation, a power-supply range of 19-300 VDC and 40-250 VAC, and communications options 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet with IRIG-B and URTD compatibility.
Yes. The EGR-5000-2B0HB0 provides generator protection with zone selective interlocking, differential, voltage, and power protection alongside metering capabilities. Its robust I/O and Ethernet communications support centralized protection logic, enabling faster fault isolation and reduced downtime in industrial plants, data centers, and utilities.
Compliance details are provided by the manufacturer; verify applicable CE, SIL readiness, and IP ratings with Eaton for this model. The product page lists 'Compliances: Contact Manufacturer,' so confirm current certifications and site-specific requirements directly with Eaton before deployment.
Warranty terms follow Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. Support includes access to Eaton documentation, datasheets, and technical assistance for installation, integration, and ongoing maintenance to sustain generator protection reliability.