Eaton EGR-5000-2B0LA0 Generator Protection Relay - 50/60 Hz
Part Number: EGR-5000-2B0LA0
Quick Summary
Eaton generator protection relay is a configurable device that monitors and protects generators in industrial power systems. Engineers often face protection misconfigurations that lead to unnecessary outages or costly trips; this model is designed to reduce false trips while delivering precise control. Compliance status for this unit should be confirmed with the manufacturer, with CE, UL, and IP considerations typical for generator protection relays in industrial environments. The EGR-5000-2B0LA0 combines robust protection with flexible interfacing, enabling scalable ambient performance and streamlined integration into existing SCADA and maintenance workflows. By delivering reliable protection alongside versatile I/O and communications, it supports safer operations, faster fault diagnosis, and improved maintenance planning for generation assets.
Product Information
Extended Description
EGR-5000-2B0LA0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, Removable, Generator, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2B0LA0
UPC
786679150238
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
2
Analog outputs
2
Base relay
EGR-5000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface IRIG-B Trip Coil Monitor
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Current Protection and Metering Power Protection and Metering Differential Protection
Zone selective interlocking
1
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: The EGR-5000-2B0LA0 provides eight digital inputs and nine digital outputs plus two analog inputs and two analog outputs, enabling comprehensive signal conditioning and event logging. This reduces wiring complexity and supports precise fault detection, lowering unplanned downtime in industrial generator sets and data centers. Application: generator protection in manufacturing plants and critical facilities. Feature → Business Impact → Application: Power supply range covers 19-300 Vdc and 40-250 Vac with 50/60 Hz compatibility, allowing seamless integration with diverse generator configurations and utility feeds. This versatility translates to faster commissioning and safer startup sequences for stand-by or prime generators. Application: retrofits and new installations where mixed source voltages are present. Feature → Business Impact → Application: Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet communications enable remote monitoring and SCADA integration, reducing on-site visits and enabling predictive maintenance. Application: utility-scale and industrial sites needing centralized protection monitoring. Feature → Business Impact → Application: I/O options URTD Interface, IRIG-B, and Trip Coil Monitor provide time synchronization and enhanced shutdown reliability, improving protection accuracy during transients. Application: critical power systems requiring tight coordination of protection signals. Feature → Business Impact → Application: Sensing inputs include Voltage Protection, Current Protection, Power Protection, and Differential Protection, delivering multi-domain fault coverage and fast clearance. Application: robust protection for generators in harsh environments, with reduced risk of misoperation. Feature → Business Impact → Application: Removable base and semi-flush mounting simplify installation and maintenance, shortening commissioning time and enabling easier retrofits. Application: field upgrades in existing plant infrastructure and modular generator houses.
Get a Quick Quote for a Eaton EGR-5000-2B0LA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EGR-5000-2B0LA0?
Enquire Now
FAQs
The relay uses a semi-flush mounting method with a removable base and removable terminals, facilitating straightforward integration into existing control panels. With 8 digital inputs, 9 digital outputs, 2 analog inputs, and 2 analog outputs, it accommodates a wide range of protection schemes and signaling without extensive re-wiring. Ensure mounting space and terminal accessibility align with the panel layout for efficient commissioning.
Power supply range is 19-300 Vdc and 40-250 Vac, with a frequency rating of 50/60 Hz. It supports multiple protection and metering domains (Voltage, Current, Power, Differential) and provides 2 analog inputs/outputs along with 8/9 IO, enabling comprehensive protection and monitoring for generator deployments.
The EGR-5000-2B0LA0 supports Mbus TCP and DNP3 TCP/UDP over LC duplex FO Enet. This enables remote monitoring, streamlined data exchange with SCADA systems, and easier integration into existing industrial Ethernet architectures, reducing onsite diagnostic visits.
Warranty terms follow Eaton Selling Policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. For certification and compliance specifics, verify with Eaton as indicated under Compliances (Contact Manufacturer).
Yes. It supports voltage, current, power, and differential protection, plus zone selective interlocking and IRIG-B-based time synchronization. This makes it suitable for critical power applications in manufacturing, data centers, and utilities where precise protection coordination and reliable trip signaling are required.