Eaton EGR-5000-2B1HA0 Generator Relay - 50/60 Hz

Part Number: EGR-5000-2B1HA0
Manufacturer
Eaton
Part number
EGR-5000-2B1HA0

Quick Summary

Eaton generator relay protects generator sets by monitoring start/stop sequences and fault conditions in industrial power systems. When misconfiguration or omissions occur, outages or equipment damage can follow, impacting uptime and operational costs. Compliance and certifications are model-specific; please verify with the manufacturer for CE marking, SIL levels, or IP ratings as required by your sector. By leveraging Ethernet connectivity and flexible I/O, this relay integrates with modern protection schemes, delivering reliable protection with scalable monitoring, streamlined maintenance, and reduced panel wiring for data centers, plants, and utilities.

Product Information

Extended Description

EGR-5000-2B1HA0 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Generator, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2B1HA0
UPC
786679153581
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
2
Analog outputs
2
Base relay
EGR-5000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input URTD Interface
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Power Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: The EGR-5000-2B1HA0 supports 61850 or Mbus TCP and DNP3 TCP/UDP over Ethernet RJ45, enabling seamless integration with SCADA and energy management systems; the result is faster fault visibility and reduced integration costs for generator protection in oil and gas, manufacturing, and data centers. Feature → Business Impact → Application: A wide power supply range of 19-300 Vdc and 40-250 Vac allows flexible installation from diverse sources, simplifying retrofits and new builds while minimizing wiring complexity across industrial sites. Feature → Business Impact → Application: Eight digital inputs, two analog inputs, two analog outputs, and nine digital outputs provide rich sensing and control, enabling complex start/stop logic, protection schemes, and coordinated tripping for reliable operations. Feature → Business Impact → Application: I/O options like IRIG-B, Trip Coil Monitor, Sensitive Ground Input, and URTD Interface enhance synchronization, ground protection, and external interfacing, reducing miscoordination and improving safety in multi-generator configurations. Feature → Business Impact → Application: Zone selective interlocking (ZSI) improves selective tripping, preserving healthy sections of a plant while isolating faults, which lowers downtime and maintenance costs in utility-scale or large manufacturing environments. Feature → Business Impact → Application: Semi-flush mounting, removable terminals, and a compact footprint streamline panel installation, reduce commissioning time, and simplify field service in space-constrained control rooms and switchgear assemblies.

Get a Quick Quote for a Eaton EGR-5000-2B1HA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EGR-5000-2B1HA0? Enquire Now

FAQs

Plan for semi-flush mounting in standard electrical panels and ensure there is accessible space for removable terminals. Align wiring with the 8 digital inputs, 2 analog inputs, 2 analog outputs, and 9 digital outputs to support efficient control logic. Use Ethernet connectivity for SCADA integration and verify proper grounding practices to optimize noise immunity.
The relay provides voltage, current, and differential protection with multiple sensing inputs, enabling rapid fault detection and coordinated trips. Its zone selective interlocking feature helps isolate faults with minimal impact, improving reliability and reducing outage scope in multi-generator systems.
Yes. The model supports I/O options that include IRIG-B timing, Trip Coil Monitor, Sensitive Ground Input, and URTD Interface, enabling precise timing synchronization and enhanced protection interfaces for mission-critical generator applications.
The relay accepts 19-300Vdc or 40-250Vac with a 50/60 Hz frequency rating, allowing flexible power sourcing for diverse facilities. Its removable terminals and compact footprint simplify wiring and panel integration, while the 8/9 I/O configuration supports complex protection and control logic.
Warranty follows Eaton Selling Policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. For technical support, refer to Eaton’s protection-relay documentation and contact the manufacturer for model-specific certification details and field-replaceable parts.