Eaton EGR-5000-2B1HA1 Generator Relay - 50/60 Hz

Part Number: EGR-5000-2B1HA1
Manufacturer
Eaton
Part number
EGR-5000-2B1HA1

Quick Summary

Eaton generator relay EGR-5000-2B1HA1 provides robust generator protection for industrial power systems. Engineers often struggle with coordinating protection logic across multiple inputs and remote monitoring. Compliances are listed as 'Contact Manufacturer'; verify CE, SIL, and IP ratings for your configuration. The device supports IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, enabling seamless integration with modern SCADA and EMS. This relay offers 8 digital inputs, 2 analog inputs, 2 analog outputs, and 9 outputs to support complex interlocking and metering schemes. This combination translates into faster fault detection, reduced downtime, and predictable protection coordination across generator sets and SCADA interfaces. Industry professionals rely on the EGR-5000-2B1HA1 to streamline commissioning, align with 50/60 Hz operations, and future-proof protection strategies.

Product Information

Extended Description

EGR-5000-2B1HA1 Eaton: Eaton, generator relay, EGR-5000, Generator protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Generator, 19-300Vdc, 40-250Vac, 50/60 Hz, ProjectionSensitive Ground Input
Product Name
Eaton generator relay
Catalog Number
EGR-5000-2B1HA1
UPC
786679148129
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Generator
Type
Generator relay
Product Category
Generator protection relay
Analog inputs
2
Analog outputs
2
Base relay
EGR-5000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Sensitive Ground Input Trip Coil Monitor URTD Interface
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Current Protection and Metering Differential Protection Power Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
The EGR-5000-2B1HA1 provides extensive digital and analog I/O along with a robust protection library, enabling tailored protection logic that reduces wiring complexity and speeds up commissioning. In practice, engineers can implement interlocks, alarms, and metering directly at the relay, improving reliability and reducing panel space. With support for IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, integration with SCADA and EMS becomes straightforward, shortening engineering cycles and improving fault visibility across multiple gensets. Its wide power supply range of 19-300 VDC and 40-250 VAC, together with 50/60 Hz compatibility, simplifies procurement and enables one platform for diverse generator configurations. Projection mounting and removable terminals streamline retrofits and field wiring, delivering faster installation and lower risk of wiring errors. Zone selective interlocking and multi-layer protection—covering voltage, current, differential, and power protection with metering—support coordinated protection and faster clearance. Finally, optional I/O features such as IRIG-B input, Trip Coil Monitor, and URTD Interface broaden compatibility for legacy and modern control systems. Warranty support and Eaton’s policy further reduce lifecycle risk and maintenance costs.

Get a Quick Quote for a Eaton EGR-5000-2B1HA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EGR-5000-2B1HA1? Enquire Now

FAQs

Begin with mounting the relay in a suitable control panel using projection mounting. Connect power from 19-300 VDC or 40-250 VAC as specified, and wire the 8 digital inputs, 2 analog inputs, 2 analog outputs, and 9 outputs according to the protection scheme. Follow the manufacturer’s wiring diagram and ensure proper grounding and shielded communication if using IEC 61850, M-Bus TCP, or DNP3 TCP/UDP protocols.
The relay supports voltage, current, differential protection, and power protection with metering, plus zone selective interlocking. It handles 8 digital inputs, 2 analog inputs, and 9 outputs to enable coordinated tripping, alarms, and interlocks. This combination improves fault discrimination, reduces unintended trips, and enhances protection coordination across generator feeders.
Yes. The device operates with 50/60 Hz systems and accepts a wide input range of 19-300 VDC or 40-250 VAC, making it compatible with diverse generator configurations. Its flexible I/O and communication options support integration into existing 50/60 Hz control architectures and SCADA networks.
The data sheet lists Compliances as 'Contact Manufacturer.' Remote verification is advised to confirm CE, SIL, IP ratings, and other certifications for your configuration. Always consult the Eaton datasheets (E-Series protective relays and EGR-5000 sheet) and confirm with the vendor before deployment.
The product is covered by Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. This warranty, plus access to Eaton’s selling policy and technical support, reduces ownership risk and downtime costs, contributing to a lower total cost of ownership over the system’s lifecycle.