Eaton EMR-3000-2A0HA0 Motor Relay - IEC 61850 over Ethernet
Part Number: EMR-3000-2A0HA0
Quick Summary
Eaton EMR-3000-2A0HA0 motor relay provides robust motor control and protection for industrial drives. Engineers often struggle with integrating reliable protection, diagnostics, and remote communication across harsh environments. The device supports IEC 61850 over Ethernet RJ-45, Modbus TCP, and DNP3 TCP, with URTD Interface and IRIG-B options for interoperability in modern automation networks. Its standard mounting, 4 digital inputs, 4 digital outputs, and current protection and metering enable faster deployment, reduced wiring, and improved energy visibility across OEMs and plant operations. This translates into shorter project timelines, lower panel space requirements, and more reliable automation performance for conveyors, pumps, and processing lines.
Product Information
Extended Description
EMR-3000-2A0HA0 Eaton: Eaton motor relay, 5A, 1A, Motor, over Ethernet RJ-45, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz, Standard mount, Current Protection and Metering, URTD Interface, IRIG-B
Product Name
Eaton motor relay
Catalog Number
EMR-3000-2A0HA0
UPC
786679145623
Product Length/Depth
8.06 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.82 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Motor
Type
Motor relay
Analog inputs
0
Phase current
5A, 1A
Analog outputs
1
Digital inputs
4
Digital outputs
4
I/O options
IRIG-B URTD Interface
IEC 61850
over Ethernet RJ-45
Modbus / DNP3 TCP
over Ethernet RJ-45
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Frequency rating
50/60 Hz
Mounting method
Standard
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - EMR-3000-2A0HA0
Voltage and frequency compatibility: The EMR-3000-2A0HA0 supports 19–300 VDC and 40–250 VAC with a 50/60 Hz rating, enabling operation across diverse power environments. Business impact: minimizes panel redesign and stock variety, accelerating installation in mixed-voltage facilities and minimizing downtime during transitions to new drives. Application: suitable for global motor control panels and OEM builds where voltage flexibility is essential. I/O and sensing integration: With 4 digital inputs, 4 digital outputs, 0 analog inputs, and built-in current protection and metering for 5A/1A phase currents, the relay reduces external hardware and simplifies energy management. Business impact: lowers BOM cost and wiring complexity while improving fault detection and energy reporting. Application: ideal for compact motor control cabinets and remote pump stations. Communication and interoperability: IEC 61850 over Ethernet RJ-45, Modbus/TCP, DNP3/TCP, plus URTD Interface and IRIG-B time synchronization options. Business impact: seamless SCADA and substation integration, faster commissioning, and easier remote diagnostics. Application: supports modern automation networks and synchronized control across multi-site installations. Physical integration and installation: Standard mounting with a compact footprint (8.06 in x 8.62 in x 6.82 in) and 5.82 lb weight; designed for straightforward panel mounting and wiring. Business impact: reduces installation time, simplifies maintenance, and fits into existing layouts. Application: OEM and industrial facilities requiring space-efficient protection relays. Warranty and support: Backed by Eaton's policy with a one-year warranty from installation or 18 months from shipment. Business impact: enhances total cost of ownership with clear support terms. Application: reliable procurement and service planning for long-term operations.
Get a Quick Quote for a Eaton EMR-3000-2A0HA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EMR-3000-2A0HA0?
Enquire Now
FAQs
The EMR-3000-2A0HA0 uses standard mounting and a compact footprint (8.06 in L x 8.62 in H x 6.82 in W) with a weight around 5.82 lb. Install in a ventilated panel, connect 4 digital inputs and 4 digital outputs, and wire the power rails for 19–300 VDC or 40–250 VAC. Verify compatibility with existing drives and ensure proper termination of communication interfaces for reliable operation.
The relay supports IEC 61850 over Ethernet RJ-45, Modbus TCP, and DNP3 TCP, enabling integration with modern SCADA, substation automation, and industrial networks. URTD Interface and IRIG-B time synchronization provide time-stamped data and precise coordination across multi-drive systems, reducing commissioning time and improving diagnostic accuracy.
It features 4 digital inputs and 4 digital outputs, with 0 analog inputs. The phase current rating is 5 A and 1 A for protection/metering, with current protection and metering functionality built into the relay. This configuration supports compact panel layouts while delivering essential motor-protection features and energy monitoring.
The device operates over 50/60 Hz with a wide voltage range of 19–300 VDC and 40–250 VAC. This broad specification makes it suitable for diverse industrial environments, enabling flexible deployment across equipment fed from DC rails or AC power supplies without needing multiple relays.
Warranty details follow Eaton policy 25-000, offering one year from the date of installation or eighteen months from the date of shipment, whichever occurs first. For formal certifications (CE, SIL, IP) and other compliance specifics, confirm with Eaton. This policy helps with planning maintenance, replacements, and long-term operational budgeting.