Eaton EMR-3000-2B1FA0 Motor Relay - IRIG-B over Fiber Optic
Part Number: EMR-3000-2B1FA0
Quick Summary
Eaton motor relay EMR-3000-2B1FA0 enables robust motor control for demanding industrial drives. Engineers often struggle with reliable remote monitoring and fault isolation across fiber links in harsh environments. This unit supports Modbus RTU or DNP3 RTU over fiber, IRIG-B time stamping, and zone-selective interlocking, helping maintain timing accuracy and selectivity. Compliances are not specified in this dataset; verify CE, IP ratings, and SIL certifications directly with Eaton to ensure regulatory alignment. With 4 inputs and 4 outputs plus integrated sensing, this relay delivers scalable control and metering options while reducing wiring complexity and installation costs.
Product Information
Extended Description
EMR-3000-2B1FA0 Eaton: Eaton, EMR-3000-2, current only motor relay, 4I, 4O, ZSI ,IRIG-B, 5/1A PH and Sens. 0.5/0.1A GND, Modbus RTU or DNP3 RTU over Fiber Optic ST, No conf. coat, Semi-flush mount
Product Name
Eaton motor relay
Catalog Number
EMR-3000-2B1FA0
UPC
786679146538
Product Length/Depth
8.06 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.82 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Motor
Type
Motor relay
Analog inputs
0
Phase current
5A, 1A
Analog outputs
0
Digital inputs
4
Digital outputs
4
I/O options
URTD Interface Sensitive Ground Input IRIG-B
Modbus / DNP3 RTU
over fiber optic ST
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Frequency rating
50/60 Hz
Mounting method
Standard
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Eaton Specification Sheet - EMR-3000-2B1FA0
Selling Policy 25-000 - Distribution and Control Products and Services
Feature → Business Impact → Application: The EMR-3000-2B1FA0 provides four digital inputs and four digital outputs, enabling flexible local control and status signaling that reduces panel wiring complexity and installation time in motor control cabinets. This translates to faster commissioning and improved troubleshooting in high-volume manufacturing lines. Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over fiber optic ST delivers EMI-resistant, long-distance communication across plant networks, improving data integrity and remote monitoring capabilities for centralized SCADA systems. Application includes large packaging lines and water/wastewater facilities where fiber reliability matters. Feature → Business Impact → Application: IRIG-B time stamping and URTD interface ensure precise timing and robust grounding references, supporting synchronous motor control and coordinated interlocking in critical processes. Application spans power distribution equipment and motor-driven systems with strict timing requirements. Feature → Business Impact → Application: Zone Selective Interlocking (1) isolates faults quickly, reducing downstream damage and downtime; this lowers MTTR and improves plant availability in high-demand environments. Application includes feeders and motor groups with tight protection coordination. Feature → Business Impact → Application: Sensing inputs with Current Protection and Metering enable proactive energy management and protective trips, improving efficiency and reducing unplanned outages. Application covers energy-intensive motors and conveyors in manufacturing. Feature → Business Impact → Application: Semi-flush/Standard mounting, 8.06 in × 8.62 in × 6.82 in, weight 5.82 lb, plus 4 I/O and Modbus/DNP3 fiber interfaces streamline installation and retrofit projects, delivering a compact, scalable solution for evolving automation architectures.
Get a Quick Quote for a Eaton EMR-3000-2B1FA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EMR-3000-2B1FA0?
Enquire Now
FAQs
EMR-3000-2B1FA0 installs using standard mounting and semi-flush options to fit compact control panels. Its dimensions are 8.06 in long, 8.62 in high, and 6.82 in deep, weighing 5.82 lb. Four digital inputs and four digital outputs plus a URTD interface simplify wiring, while fiber-based Modbus RTU or DNP3 RTU communication provides EMI immunity in harsh environments.
Current protection and metering monitor phase currents at 5 A and 1 A, enabling timely protection and data for energy management. Zone selective interlocking speeds fault isolation, reducing downstream damage and downtime. The integrated 4 I/O and sensing enable precise motor protection while preserving local control and remote diagnostics for motor-driven processes in manufacturing lines.
Yes. EMR-3000-2B1FA0 supports Modbus RTU and DNP3 RTU over fiber optic ST, enabling robust, EMI-resistant communication across plant networks. This supports integration with SCADA/PLC systems. Ensure host device compatibility and verify fiber length and connectors meet installation requirements for reliable operation.
Compliances in the datasheet are listed as 'Contact Manufacturer' for confirmation. Before deployment, verify CE, SIL, and IP certifications directly with Eaton to ensure regulatory alignment. Also review Eaton's warranty policy and installation guidelines to confirm service terms and long-term support for industrial applications.
By integrating four digital I/O, current protection, and fiber-ready communication, wiring is reduced, troubleshooting is simplified, and uptime improves. Zone selective interlocking accelerates fault clearance, lowering maintenance costs and energy waste. The built-in protection and remote diagnostics support faster MTTR and a favorable total cost of ownership over the motor drive lifecycle.