Part Number: EMR-4000-2A1CA1
Quick Summary
The Eaton motor relay EMR-4000-2A1CA1 enables robust motor control in automation panels. Engineers often wrestle with protecting equipment while keeping control networks simple and reliable in harsh industrial environments. Certification details vary by region; consult the manufacturer for CE, UL, or IP ratings applicable to your site. Powered by protective and metering sensing across Voltage, Current, and Power, it supports 19–300 VDC and 40–250 VAC, with URTD and IRIG-B interfaces. In practice, this translates to faster commissioning, enhanced protection, and lower energy costs for industrial automation projects. With Modbus and DNP3 RTU over Ethernet, 8 digital inputs, 4 analog outputs, 5 digital outputs, 5 A and 1 A phase currents, the EMR-4000-2A1CA1 integrates seamlessly with existing plant controls.
Product Information
Extended Description
EMR-4000-2A1CA1 Eaton: Eaton, motor relay, 5A, 1A, Motor, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, Power Protection and Metering,Voltage Protection and Metering,Current Protection and Metering,URTD Interface,Sensitive Ground Input
Product Name
Eaton motor relay
Catalog Number
EMR-4000-2A1CA1
UPC
786679147030
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Motor
Type
Motor relay
Analog inputs
0
Phase current
5A, 1A
Analog outputs
4
Digital inputs
8
Digital outputs
5
I/O options
IRIG-B URTD Interface Sensitive Ground Input
Modbus / DNP3 RTU
over Ethernet RJ-45
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - EMR-4000-2A1CA1
URTD Interface and IRIG-B time synchronization enable precise coordination across distributed protection schemes, reducing mis-timed events and false trips in large motor drives and networked installations. This capability directly improves system reliability and simplifies fault diagnosis in automation panels. Protection and metering across Voltage, Current, and Power enhances energy management and accelerates fault localization, delivering measurable reductions in downtime and energy waste. Flexible communication and I/O—Modbus / DNP3 RTU over Ethernet RJ-45, 8 digital inputs, 5 digital outputs, 4 analog outputs—facilitate direct PLC/SCADA integration, reducing wiring complexity and speeding commissioning. The option for URTD Interface and Sensitive Ground Input supports safety-critical installations with robust grounding references and precise signal conditioning. The 19–300 VDC / 40–250 VAC range accommodates multi-source power feeds, simplifying standardization across a facility. A compact footprint (8.06 in L × 8.7 in H × 9.72 in W) and a 9.259 lb weight ease panel layout, while Eaton’s warranty (25-000 policy) adds value during system deployment. Zone selective interlocking (1) further enhances fault isolation and workforce safety in dynamic motor networks.
Get a Quick Quote for a Eaton EMR-4000-2A1CA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EMR-4000-2A1CA1?
Enquire Now
FAQs
EMR-4000-2A1CA1 provides compatible motor relay functionality with up to 8 digital inputs, 5 digital outputs, and 4 analog outputs, enabling seamless cohabitation with existing Eaton E-Series devices. It supports Modbus / DNP3 RTU over Ethernet for PLC integration, reducing wiring changes and enabling centralized protection and metering across motors in automation panels.
This relay handles 5 A and 1 A phase currents and operates from 19–300 VDC and 40–250 VAC. Plan wiring to accommodate dual-source power where missions require DC and AC motor feeds, and ensure protected grounding with the URTD/Sensitive Ground Input as specified to maintain signal integrity and safety.
Yes. The device combines motor protection and metering with IRIG-B time sync and URTD interface, enabling precise fault signaling and safe interlock in line-side protection. Its 8 digital inputs, 5 digital outputs, and 4 analog outputs support complex control logic, reducing downtime and improving line reliability.
Compliances are listed as ‘Contact Manufacturer’ for this model. Certification availability (CE, UL, IP ratings) varies by region and installation. Verify with Eaton for your country and application; include your environment, enclosure type, and any regulatory requirements during specification to ensure compliance.
The integrated protection, metering, and flexible I/O reduce wiring, speed up commissioning, and enable energy monitoring, which lowers startup time, maintenance costs, and energy waste. Coupled with zone selective interlocking and robust network support, this translates to lower total cost of ownership for industrial automation projects.