Eaton EMR-5000-2A0BA1 Motor Relay - Modbus RS485
Part Number: EMR-5000-2A0BA1
Quick Summary
Eaton EMR-5000-2A0BA1 motor relay protects motors in industrial automation and control panels. This device addresses downtime caused by unprotected starts and fault conditions by delivering differential protection, programmable inputs, and remote communication. While ensuring robust protection, consider common standards such as CE and SIL where applicable, and confirm enclosure and safety certifications with the manufacturer. With Modbus RTU or DNP3 RTU over RS-485, plus 16 digital inputs and 9 digital outputs, it offers scalable control for complex motor circuits. The model supports 50/60 Hz operation and a wide input range, delivering reliable performance in demanding environments and enabling cost-effective panel fabrication and maintenance.
Product Information
Extended Description
EMR-5000-2A0BA1 Eaton: Eaton, motor relay, EMR-4000, 19-300 Vdc, 40-250 Vac, Motor protection relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 16, 9, Removable, Motor, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Differential Protection,
Product Name
Eaton motor relay
Catalog Number
EMR-5000-2A0BA1
UPC
786679159347
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Motor
Type
Motor relay
Product Category
Motor protection relay
Base relay
EMR-4000
Analog inputs
0
Communication
Modbus RTU or DNP3 RTU over RS485
Phase current
5A, 1A
Analog outputs
0
Digital inputs
16
Digital outputs
9
I/O options
URTD Interface IRIG-B
Modbus / DNP3 RTU
over RS-485
Sensing inputs
Power Protection and Metering Current Protection and Metering Voltage Protection and Metering Differential Protection
Zone selective interlocking
1
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - EMR-5000-2A0BA1
Feature: RS-485 communication with Modbus RTU or DNP3 RTU enables seamless integration into SCADA and PLC networks → Business Impact: Reduces wiring complexity and enables remote monitoring and diagnostics, cutting field maintenance visits. Application: Suitable for motor protection in automation lines where centralized control is needed. Feature: 16 digital inputs and 9 digital outputs with removable terminals → Business Impact: Flexible I/O mapping supports zone selective interlocking and event-driven protection, improving fault containment and system reliability. Application: Best for switchgear and motor control centers requiring modular I/O. Feature: Sensing and protection suites including Power Protection, Metering, Voltage/Current protection, and Differential Protection → Business Impact: Enhances safety margins and prevents motor damage under transient faults, lowering total cost of ownership. Application: Critical in high-demand motor feeders and process lines. Feature: Base EMR-4000 compatibility with 19-300 Vdc and 40-250 Vac inputs → Business Impact: Simplifies upgrades and spare parts planning, reducing engineering time and inventory cost. Application: retrofit projects and new builds alike. Feature: Projection mounting and removable terminals → Business Impact: Easy installation and maintenance in tight panel spaces, minimizing downtime and wiring errors. Application: Enclosures with limited access and frequent reconfiguration. Feature: Zone selective interlocking (1) and IRIG-B I/O option → Business Impact: Enables fast fault isolation and precise protection coordination, improving uptime in multi-mfeed configurations. Application: Industrial feeders where selective tripping is essential. Feature: 50/60 Hz compatibility and wide voltage range → Business Impact: Broad applicability across global facilities, reducing the need for multiple regional variants. Application: International deployments and cross-site consolidation.
Get a Quick Quote for a Eaton EMR-5000-2A0BA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EMR-5000-2A0BA1?
Enquire Now
FAQs
Install the device using the projection mounting method, connect the removable terminals for power and I/O, then configure Modbus RTU or DNP3 RTU over RS-485. Leverage the 16 digital inputs and 9 digital outputs to map to your control scheme and enable zone selective interlocking for fast fault isolation.
It operates on 19–300 Vdc or 40–250 Vac at 50/60 Hz, features 5A and 1A phase current options, 16 digital inputs, 9 digital outputs, and supports Modbus RTU or DNP3 RTU over RS-485 for remote communication.
Yes. The EMR-5000-2A0BA1 includes differential protection and power metering capabilities, providing enhanced fault detection and motor protection in demanding applications.
Certification details are provided by the manufacturer and should be confirmed with Eaton for your region and application. Look for CE marking and other safety certifications as required by your facility standards.
Warranty follows Eaton’s policy: one year from installation or eighteen months from shipment, whichever comes first. For service, spare parts, or RMA guidance, contact Eaton support or your authorized distributor.