Eaton EMR-5000-2A0GB0 Motor Relay - Differential Protection

Part Number: EMR-5000-2A0GB0
Manufacturer
Eaton
Part number
EMR-5000-2A0GB0

Quick Summary

Eaton motor relay is a robust control device that protects and coordinates motor operation in industrial drives. Engineers often struggle with integrating protection logic, fault isolation, and reliable communications in a single enclosure. In practice, motor protection relays from Eaton align with industry standards such as SIL-rated protection, CE considerations, and IP-rated housings; please verify current certifications with Eaton for EMR-5000-2A0GB0. This solution combines differential protection, Modbus RTU or DNP3 RTU over RS-485, and flexible I/O to streamline motor protection programs, reduce downtime, and lower wiring and panel complexity.

Product Information

Extended Description

EMR-5000-2A0GB0 Eaton: Eaton, motor relay, EMR-4000, 19-300 Vdc, 40-250 Vac, Motor protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 16, 9, Removable, Motor, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz Differential Protection
Product Name
Eaton motor relay
Catalog Number
EMR-5000-2A0GB0
UPC
786679160060
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Motor
Type
Motor relay
Product Category
Motor protection relay
Base relay
EMR-4000
Analog inputs
0
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Phase current
5A, 1A
Analog outputs
0
Digital inputs
16
Digital outputs
9
I/O options
URTD Interface IRIG-B
Modbus / DNP3 RTU
D-Sub / RS-485
Sensing inputs
Differential Protection Voltage Protection and Metering Power Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
The EMR-5000-2A0GB0 offers differential protection and sensing across voltage, current, and metering inputs, delivering a fast fault signal that minimizes equipment damage and downtime. This translates to a measurable business impact: higher motor availability, fewer unplanned outages, and improved maintenance planning for power distribution in manufacturing settings. It supports a robust application footprint in motor control panels and drive systems, enabling precise coordination with factory SCADA and energy management systems through Modbus RTU or DNP3 RTU over RS-485, reducing integration time and risk. With 16 digital inputs and 9 digital outputs, operators gain flexible signaling and interlocking capabilities for safe, loop-free control of multiple motor circuits in demanding environments. The URTD interface IRIG-B option ensures time synchronization for accurate event logging in critical power applications. Removable terminals and compatibility with the EMR-4000 base relay simplify retrofit projects, cut commissioning time, and streamline field servicing. The product’s 50/60 Hz operation and wide DC/AC voltage range (19-300 Vdc / 40-250 Vac) expand applicability across diverse motor types, delivering a consistent protection layer from installation to operation. A single, ready-to-integrate device also supports warranty and service programs from Eaton, reducing lifecycle risk and administrative overhead for procurement teams.

Get a Quick Quote for a Eaton EMR-5000-2A0GB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EMR-5000-2A0GB0? Enquire Now

FAQs

When retrofitting an EMR-5000-2A0GB0, plan for semi-flush mounting and removable terminals to streamline wiring and future service. The unit is designed to be compatible with the EMR-4000 base relay, enabling straightforward upgrades without a full panel redesign. Ensure RS-485 Modbus RTU or DNP3 RTU networks are correctly terminated and that the 16 digital inputs and 9 digital outputs align with your motor control wiring diagrams for safe control signaling.
Differential protection enables fast detection of internal motor faults by comparing signals across essential parameters, triggering protective actions before damage propagates. This reduces unplanned downtime and extends motor life by isolating faults promptly. In practice, combine this with voltage, current, and metering inputs to create a comprehensive protection scheme in power distribution and drive applications.
Yes, the EMR-5000-2A0GB0 supports Modbus RTU or DNP3 RTU over RS-485. To configure, connect the RS-485 interface to your SCADA or RTU network, set the appropriate baud rate and addressing, and map the device’s DI/DO and protection status to your client tags. This enables remote monitoring, alarms, and control signaling with minimal wiring and fast integration into existing automation architectures.
The product is covered by Eaton’s warranty policy: one year from the date of installation or eighteen months from shipment, whichever occurs first. Compliances are listed as Contact Manufacturer, so verify current CE, IP, or SIL-related certifications with Eaton for your specific deployment and regulatory requirements prior to purchase or field deployment.
This motor protection relay excels in industrial motor control panels, power distribution units, and drive systems across manufacturing, process automation, and utility subsections. Its differential protection, wide voltage range, and RS-485 communication make it ideal for environments requiring reliable protection, precise logging, and scalable integration with SCADA and energy management systems.