Eaton motor relay EMR-5000-2A1IB1 - 50/60 Hz, RS-485 & Ethernet
Part Number: EMR-5000-2A1IB1
Quick Summary
Eaton motor relay EMR-5000-2A1IB1 provides motor protection and control for automation systems and machinery. Engineers often struggle to protect motors from overloads, misoperations, and unexpected faults that trigger costly downtime. Compliance details are provided by the manufacturer and may include CE marking, IP ratings, or SIL considerations depending on region; verify with Eaton. With RS-485 and Ethernet TCP connectivity and a voltage range of 19–300 Vdc and 40–250 Vac, this relay supports scalable monitoring and quick fault diagnosis. The design supports up to 16 digital inputs, 9 digital outputs, and 5 A/1 A phase current, enabling reliable protection across diverse motor applications. This translates to improved uptime, simpler integration, and long-term asset protection for industrial plants.
Product Information
Extended Description
EMR-5000-2A1IB1 Eaton: Eaton, motor relay, EMR-4000, 19-300 Vdc, 40-250 Vac, Motor protection relay,5A, 1A, 16, 9, Removable, Motor, over RS-485, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton motor relay
Catalog Number
EMR-5000-2A1IB1
UPC
786679159514
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Motor
Type
Motor relay
Product Category
Motor protection relay
Base relay
EMR-4000
Analog inputs
0
Phase current
5A, 1A
Analog outputs
0
Digital inputs
16
Digital outputs
9
I/O options
Sensitive Ground Input IRIG-B URTD Interface
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
1
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Eaton Specification Sheet - EMR-5000-2A1IB1
Wide voltage and protection range enables investment protection across both DC and AC motors, supporting 19–300 Vdc and 40–250 Vac with 50/60 Hz operation. This delivers a tangible business impact by reducing the incidence of nuisance trips and enabling seamless operation in mixed-voltage facilities; ideal for manufacturing and processing lines where uptime is critical. The EMR-5000-2A1IB1 offers 16 digital inputs and 9 digital outputs, enabling sophisticated interlocks and logic control that translate to faster fault detection and safer start-up sequences. In practice, this means fewer manual interventions and more predictable plant performance, which is essential for OEMs and end users deploying multi-motor systems. Removable terminals simplify installation and maintenance, saving service time during commissioning and field upgrades, while compatibility with the EMR-4000 base relay ensures a scalable protection architecture for growing plants. RS-485 and Ethernet TCP communications enable remote monitoring and integration with SCADA, PowerPort-E workflows, and Eaton’s E-Series ecosystem, improving visibility and reducing on-site maintenance visits. The sensing inputs cover Voltage, Power, Current Protection and Metering, plus Differential Protection, delivering comprehensive protection that supports energy efficiency initiatives, accurate fault analysis, and compliance with utility requirements. Zone selective interlocking (ZSI) of 1 enhances selective fault isolation, reducing damage and downtime in fault events. Overall, the device aligns with ongoing Industry 4.0 initiatives by enabling data-driven maintenance and faster troubleshooting while supporting a global 50/60 Hz footprint for international deployments.
Get a Quick Quote for a Eaton EMR-5000-2A1IB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EMR-5000-2A1IB1?
Enquire Now
FAQs
Begin by confirming mechanical compatibility with the EMR-4000 base relay and ensure projection mounting is appropriate for your panel. Remove terminals for easier wiring, then connect 16 digital inputs and 9 digital outputs as per the control schematic. The removable terminals simplify field installation and future maintenance, while RS-485 and Ethernet interfaces are ready for Modbus RTU/TCP integration with your PLC or SCADA system.
The device supports 19–300 Vdc and 40–250 Vac with a 50/60 Hz frequency rating. It provides 5 A and 1 A phase current, 16 digital inputs, and 9 digital outputs. Communications include Modbus over RS-485 and Modbus TCP over Ethernet RJ-45, enabling robust remote monitoring and integration with existing control architectures.
Yes. The EMR-5000-2A1IB1 includes Zone Selective Interlocking (ZSI) capability with a 1-flag setting, allowing faster fault isolation and reduced damage to motor circuits. When paired with the EMR-4000 base and appropriate protective configurations, the relay supports comprehensive protection schemes for multi-motor drives in plant automation.
Compliance details are provided by the manufacturer and may include CE, IP ratings, or SIL considerations depending on the region. For definitive certification status and the exact standards applicable to your project, consult Eaton’s documentation or contact Eaton support to obtain the latest certificates and test reports specific to EMR-5000-2A1IB1.
The relay offers remote monitoring via RS-485 and Ethernet, removable terminals for fast maintenance, and a wide voltage range to reduce parts variety. These features collectively shorten maintenance windows, enable early fault detection, and improve uptime. Over time, this translates to lower unplanned downtime costs, easier upgrades, and better asset protection for industrial motor fleets.