Eaton EMR-5000-2B1BA1 motor relay - Modbus RTU/DNP3 over RS-485

Part Number: EMR-5000-2B1BA1
Manufacturer
Eaton
Part number
EMR-5000-2B1BA1

Quick Summary

The Eaton EMR-5000-2B1BA1 motor relay provides advanced motor protection and control for industrial drives. This unit addresses common engineering challenges such as wiring complexity, integration with Modbus RTU or DNP3 RTU over RS-485, and field maintenance. In motor protection relays, robust performance is often tied to clear wiring, reliable communication, and strong protection logic; this model supports those needs with removable terminals, projection mounting, and precise input/output options. While many users expect CE, IP and SIL-related considerations, always verify compliances with the manufacturer for your specific installation. Leveraging the EMR-4000 base enables scalable protection, while RS-485 communications and 50/60 Hz operation deliver value across diverse plant environments and motor types.

Product Information

Extended Description

EMR-5000-2B1BA1 Eaton: Eaton, motor relay, EMR-4000, 19-300 Vdc, 40-250 Vac, Motor protection relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 8, 9, Removable, Motor, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton motor relay
Catalog Number
EMR-5000-2B1BA1
UPC
786679159125
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Motor
Type
Motor relay
Product Category
Motor protection relay
Base relay
EMR-4000
Analog inputs
2
Communication
Modbus RTU or DNP3 RTU over RS485
Phase current
5A, 1A
Analog outputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Sensitive Ground Input URTD Interface
Modbus / DNP3 RTU
over RS-485
Sensing inputs
Differential Protection Power Protection and Metering Voltage Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Feature: RS-485 communication with Modbus RTU or DNP3 RTU over RS-485 enables remote monitoring and integration with SCADA systems. Business impact: reduces on-site visits, speeds fault diagnosis, and improves fleet-wide visibility for preventive maintenance. Application: motor protection in conveyors, pumps, and fans where centralized control is required. Feature: Wide power supply range, 19-300 Vdc and 40-250 Vac, supports diverse motor voltages. Business impact: simplifies inventory and minimizes rewiring during upgrades. Application: mixed-voltage motor parks and retrofits in manufacturing lines. Feature: Flexible I/O with 2 analog inputs, 2 analog outputs, 8 digital inputs, and 9 digital outputs. Business impact: granular monitoring and control for efficiency metrics and protection schemes. Application: differential protection, metering, and interlocking in medium-voltage drives. Feature: Projection mounting and removable terminals for quick installation and serviceability. Business impact: shorter commissioning times and easier field maintenance, reducing downtime. Application: panel-friendly integration in machine rooms and substations. Feature: I/O options including IRIG-B, Sensitive Ground Input, URTD Interface support, and Zone Selective Interlocking. Business impact: enables precise timekeeping, enhanced safety, and coordinated tripping across protected zones. Application: complex protection architectures in plant-wide motor drives. The combination of these features supports measurable gains in reliability, compliance readiness, and total cost of ownership for motor protection relays in industrial automation.

Get a Quick Quote for a Eaton EMR-5000-2B1BA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EMR-5000-2B1BA1? Enquire Now

FAQs

This Eaton relay uses removable terminals to simplify wiring and maintenance, while projection mounting supports stable installation in control panels. Plan for accessible wiring paths, proper torque on terminals, and clear labeling to speed future service. The removable terminals also enable easier inspection and replacement of I/O cables without full disassembly.
The device provides 2 analog inputs, 2 analog outputs, 8 digital inputs, and 9 digital outputs, plus 5A/1A phase current handling. With 50/60 Hz operation and integrated protection/reasoning for Differential, Power, Voltage, and Current metering, it enables precise protection logic and fast fault annunciation suitable for complex motor protection schemes.
Yes. The EMR-5000-2B1BA1 supports Modbus RTU or DNP3 RTU over RS-485, enabling seamless integration with standard SCADA and protection systems. This interoperability reduces integration risk and supports remote monitoring and coordinated protection actions across multiple devices.
Compliances are listed as Contact Manufacturer for this model, so verify with Eaton for your region and application. While generic industry practice favors CE marking and IP ratings, confirm the exact certifications applicable to your installation and ensure compatibility with your safety and electrical codes.
Adopting this relay can reduce downtime through improved diagnostics and remote monitoring via RS-485, streamline maintenance with removable terminals, and enable scalable protection with the EMR-4000 base. These factors typically translate to lower maintenance costs, faster fault resolution, and longer motor life in a high-demand manufacturing environment.