Eaton EMR-5000-2B1KB0 motor relay - 50/60 Hz, 5A/1A protection

Part Number: EMR-5000-2B1KB0
Manufacturer
Eaton
Part number
EMR-5000-2B1KB0

Quick Summary

Eaton EMR-5000-2B1KB0 motor relay protects industrial motors in control panels and drive systems. In fast-paced environments, unreliable fault isolation can lead to costly downtime and missed production targets. Compliance details are provided by the manufacturer; confirm CE, IP, or SIL ratings directly to ensure your site requirements are met. With Ethernet-enabled communications and robust sensing inputs, this solution delivers reliable data, reduces wiring time, and supports scalable automation. The device supports IEC 61850 and Modbus/DNP3 TCP over fiber, enabling seamless integration with modern power and automation networks. Designed for motor protection relay applications, it operates on 19–300 Vdc and 40–250 Vac with a compact footprint for dense panel layouts.

Product Information

Extended Description

EMR-5000-2B1KB0 Eaton: Eaton, motor relay, EMR-4000, 19-300 Vdc, 40-250 Vac, Motor protection relay,5A, 1A, 8, 9, Removable, Motor, over LC duplex fiber optic Ethernet, Conformal Coated Circuit Boards, 19-300Vdc, 40-250Vac, 50/60 Hz
Product Name
Eaton motor relay
Catalog Number
EMR-5000-2B1KB0
UPC
786679160022
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Motor
Type
Motor relay
Product Category
Motor protection relay
Base relay
EMR-4000
Analog inputs
2
Phase current
5A, 1A
Analog outputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Sensitive Ground Input IRIG-B
IEC 61850
over LC duplex fiber optic Ethernet
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
I/O flexibility with eight digital inputs, nine digital outputs, two analog inputs, and two analog outputs, plus removable terminals. This configuration reduces wiring complexity and installation time, improving commissioning efficiency for motor protection relay projects. In practical terms, technicians can tailor I/O to the motor control sequence, enabling precise monitoring and interlocks in compact control panels. Communication and interoperability are enhanced by IEC 61850 over LC duplex fiber optic Ethernet and Modbus/DNP3 TCP over fiber, delivering unified data exchange and easier integration with modern automation networks for substations and manufacturing floors. Protection features include voltage, current, differential protection and metering, enabling early fault detection and reducing unplanned downtime in drive systems and power management. Base compatibility with EMR-4000 and the URTD Interface options provides a clear upgrade path and simplified retrofit in existing installations. A rugged design with conformal coating and a wide operating range (19–300 Vdc / 40–250 Vac, 50/60 Hz) supports dense panel layouts and challenging environments, while 5A/1A phase current ratings ensure reliable protection for motor loads.

Get a Quick Quote for a Eaton EMR-5000-2B1KB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EMR-5000-2B1KB0? Enquire Now

FAQs

Begin with the EMR-4000 base, then connect the removable terminals for the digital, analog, and I/O channels. Use the 8 digital inputs and 9 digital outputs for the motor sequence and interlocks, and secure the unit within a rated enclosure to maintain environmental protection and wiring integrity. Follow the manufacturer’s wiring diagrams for proper power, control, and communication connections.
Voltage reach is 19–300 Vdc and 40–250 Vac, with a 50/60 Hz frequency rating. Phase current support is 5A and 1A, and the device provides 2 analog inputs, 2 analog outputs, 8 digital inputs, and 9 digital outputs, enabling versatile motor protection and control schemes.
Yes. The EMR-5000-2B1KB0 supports IEC 61850 and Modbus/DNP3 TCP communications over LC duplex fiber optic Ethernet, allowing seamless integration with modern substation and plant automation networks and enabling centralized monitoring and control.
Ideal for motor protection relay applications in automation panels, drive systems, and power management setups. With zone selective interlocking and metering capabilities, it supports safe motor start/stop sequences, fault isolation, and data-rich diagnostics for predictive maintenance and reduced downtime.
Warranty follows Eaton policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. For specific regional coverage, installation guidance, and firmware updates, contact Eaton or your authorized distributor.