Eaton EPC36B Globe & Guard - IP66, 4X HazLoc Certified
Part Number: EPC36B
Quick Summary
The Eaton EPC36B Globe & Guard is a robust hazardous-location lighting fixture designed for ceiling-mmounted illumination in Class I, Division 1 environments. Engineers often struggle with maintaining reliable light levels where explosions or dust hazards exist, and downtime can be costly. This luminaire aligns with NEC/CEC standards and delivers IP66 protection, NEMA 4X durability, and a hazardous-area rating for Class I, Division 1 and 2. By choosing EPC36B, you gain a resilient, easy-to-install solution that reduces maintenance cycles and supports compliant, long-term operation in demanding industrial settings. The combination of brass guard, tempered glass globe, and ceiling-mount design also supports safe, hands-off servicing and predictable performance across shifts.
Product Information
Extended Description
EPC36B Eaton: Eaton Crouse-Hinds series Pauluhn EP globe and guard, Medium base, 50/60 Hz, Clear tempered glass globe, With cast brass guard, Incandescent, Brass, A-19 max. lamp size, Ceiling mount, 30° angled reflector, 250 Vac, 100W
Product Name
Eaton Crouse-Hinds series Pauluhn EP globe and guard
Catalog Number
EPC36B
UPC
662276391215
Product Length/Depth
6.25 in
Product Height
12.5 in
Product Width
6.25 in
Product Weight
23 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 1 Class I, Division 2
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
Brass
Mounting Method
Ceiling
Reflector type
30° angle
Wattage
2 x 27W
Lamp type
Incandescent
Lamp size - max
A-19
Base type
Medium
Guard type
With cast guard
Voltage rating
250 Vac
Frequency rating
50/60 Hz
Globe color
Clear
Globe material
Tempered glass
Guard material
Brass
Crouse-Hinds series Pauluhn EP Fluorescent catalog page
IF LBL1415 - EP Fluorescent - Ceiling Mount
Eaton Specification Sheet - EPC36B
Feature → Business Impact → Application: The EPC36B uses a brass guard and tempered glass globe to resist impact and corrosion, delivering confidence in mission-critical lighting. This reduces replacement intervals and lowers total cost of ownership for plants requiring reliable illumination in harsh environments. Application: Industrial facilities with dust, moisture, and corrosive atmospheres benefit from its IP66/NEMA 4X protection, enabling safer nighttime operations and improved worker visibility. Feature → Business Impact → Application: The fixture supports a 30° angle reflector and ceiling mounting, enabling optimized light distribution for work cells, aisles, and equipment bays. Application: Warehouse and manufacturing floors seeking targeted lighting while preserving ceiling aesthetics. Feature → Business Impact → Application: With 250 Vac and 50/60 Hz compatibility, it supports standard power systems, minimizing wiring complexity and install time. Application: Retrofit or new builds across diverse sites, reducing commissioning risk. Feature → Business Impact → Application: The combination of 2 x 27W incandescent lamps offers reliable brightness in hazardous locations, ensuring consistent output during critical processes. Application: Control rooms, load bays, and maintenance corridors where dependable illumination is essential. Feature → Business Impact → Application: The unit’s exterior and guard materials meet demanding regulatory expectations, helping maintain compliance and audit readiness. Application: Environments requiring NEC/CEC, Class I Division 1/2 ratings and IP66 protection, such as oil & gas, chemical processing, and mining.
Get a Quick Quote for a Eaton EPC36B
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EPC36B?
Enquire Now
FAQs
Installation should begin with verifying Class I, Division 1/2 suitability and ensuring power is de-energized. Mount the fixture to a suitable ceiling support, connect the 250 Vac supply to the medium base socket, and secure the brass guard and tempered-glass globe. Use caution around hot surfaces and ensure proper sealing for IP66 protection. Consult the installation sheet for ceiling-mount guidelines and reflector orientation for optimal light distribution.
The EPC36B carries NEC/CEC compliance, IP66 ingress protection, and NEMA 4X rating. It is approved for Hazardous/Classified Locations with NEC hazardous ratings of Class I, Division 1 and Class I, Division 2. These certifications support safe operation in potentially explosive atmospheres and corrosive environments, aiding regulatory adherence and project documentation.
Yes. The EPC36B is configured for incandescent operation with a Medium base and supports two 27W lamps, compatible with A-19 lamp size. It mounts on ceilings and uses a 30° reflector to optimize light throw. This combination provides reliable performance in hazardous locations while simplifying retrofit or new-installation wiring and mounting choices.
This luminaire is designed for Hazardous/Classified Locations with IP66 protection and NEMA 4X durability, making it suitable for oil and gas facilities, chemical processing plants, mining sites, and other harsh industrial environments. The brass guard and tempered glass globe protect against impact and corrosion, supporting long service life in challenging conditions.
Maintenance is simplified by a robust brass guard and tempered-glass globe, reducing frequency of replacements in tough environments. While it uses incandescent lamps, the fixture’s solid build minimizes downtime during servicing. ROI comes from lower unplanned downtime, regulatory compliance, and predictable performance in hazardous areas, with longer intervals between structural or protective component replacements.