Eaton ETR-4000-2A0CA0 Transformer Relay - 50/60 Hz

Part Number: ETR-4000-2A0CA0
Manufacturer
Eaton
Part number
ETR-4000-2A0CA0

Quick Summary

Eaton transformer relay delivers robust transformer protection and monitoring for industrial power networks. Engineers often struggle with integrating protective relays into existing control schemes, diagnosing faults quickly, and coordinating trips across multiple devices. Certification details should be confirmed with the manufacturer; when available, CE compliance, IP ratings, and SIL support are common in this class. The device supports Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45 for seamless data exchange, and its eight digital inputs plus nine outputs provide scalable protection logic for transformer assets in diversified installations.

Product Information

Extended Description

ETR-4000-2A0CA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, , over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A0CA0
UPC
786679155356
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
Feature → Business Impact → Application: The ETR-4000-2A0CA0 offers eight digital inputs and nine digital outputs with two current sensing inputs and removable terminals. This configuration enables configurable protection schemes and streamlined field wiring, reducing installation time and wiring errors while supporting complex transformer protection logic in substations and distributed energy systems. Application: transformer protection relays in medium- to high-power networks, enabling rapid trip coordination and fault logging to improve reliability and diagnostics. Feature → Business Impact → Application: Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45 provides open, standards-based communication. Benefit: seamless integration with SCADA, historian, and remote monitoring platforms, minimizing engineering effort and improving outage response. Application: plant-wide protection monitoring and remote diagnostics across multiple transformers. Feature → Business Impact → Application: Power supply range of 19-300 Vdc or 40-250 Vac allows operation from diverse plant power systems. Benefit: single-model flexibility across sites with different electrical infrastructures, reducing inventory and increasing deployment speed. Application: new builds and retrofits where supply voltage varies by region. Feature → Business Impact → Application: URTD interface, Trip Coil Monitor, and IRIG-B options enhance trip accuracy and time-stamping. Benefit: improved protection coordination, event traceability, and forensic diagnostics. Application: zone selective interlocking and precise event logging in large transformer banks. Feature → Business Impact → Application: 50/60 Hz frequency rating and differential/current protection and metering capabilities. Benefit: accurate protection settings aligned to utility or OEM standards, with measurable performance gains in reliability and safety. Application: protecting power transformers in critical processes and data centers, ensuring uptime and regulatory compliance.

Get a Quick Quote for a Eaton ETR-4000-2A0CA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A0CA0? Enquire Now

FAQs

The ETR-4000-2A0CA0 is designed with removable terminals and a semi-flush mounting method, facilitating straightforward field wiring and service. Plan for eight digital inputs and nine outputs, ensure proper copper conduc tors are used, and verify mounting clearance for the 8.7 in height and 9.72 in width specifications. Compatibility with URTD, IRIG-B, and Trip Coil Monitor options should be verified during installation planning.
Key specs include eight digital inputs, nine digital outputs, two current sensing inputs, 50/60 Hz operation, and a power supply range of 19-300 VDC or 40-250 VAC. It supports Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45, with differential protection, current protection, metering capabilities, and Zone Selective Interlocking (2). These features enable precise transformer protection and diagnostics.
Yes. The ETR-4000-2A0CA0 uses Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45 for field communication, enabling integration with modern SCADA, MES, and protection systems. This compatibility supports remote monitoring, event logging, and centralized control, reducing on-site maintenance and speeding fault isolation across transformer fleets.
The unit includes Zone Selective Interlocking (2) and offers Trip Coil Monitor and IRIG-B interface options. This combination enables precise trip coordination across transformer banks and accurate time-stamping for event logs, improving selectivity and reducing the risk of unnecessary outages in complex substation configurations.
Warranty is governed by Eaton's policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. For maintenance and support, refer to the Eaton Selling Policy and contact Eaton support channels to obtain software updates, spare parts, and guidance on configuration optimization and lifecycle management.