Eaton transformer relay ETR-4000-2A0EB0 protects transformer banks and monitors critical parameters in industrial power systems. This device addresses the common pain point of difficult fault diagnosis and challenging network integration by delivering clear diagnostics and a robust communications interface. Certifications and compliance are documented as Compliances: Contact Manufacturer; check the Eaton datasheet for CE, SIL or IP ratings applicable to your region. For OEMs and maintenance teams, the combination of Profibus-DP over RS-485, eight digital inputs, nine outputs, and a dual power supply range (19-300 Vdc, 40-250 Vac) enables seamless installation with existing control architectures. The result is improved system reliability, faster fault isolation, and reduced downtime, supported by Eaton transformer protection expertise and global service.
Product Information
Extended Description
ETR-4000-2A0EB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz ,Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A0EB0
UPC
786679154915
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B URTD Interface Trip Coil Monitor
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Eaton Specification Sheet - ETR-4000-2A0EB0
Robust protection logic reduces fault propagation and short-circuit risk, translating to lower downtime and safer operation. The ETR-4000-2A0EB0 implements differential protection and current-sensing inputs to detect anomalies quickly, enabling proactive trips and selective coordination across feeders. This is ideal for OEM equipment and plant-wide transformer protection where reliability and rapid fault isolation are critical. Flexible I/O and communications provide eight digital inputs, nine outputs, and two current-sensing inputs, enabling ample control, metering, and signaling points for complex protection schemes. Coupled with Profibus-DP over D-Sub/RS-485, it integrates cleanly with existing PLCs and SCADA systems, reducing wiring and engineering time while improving data visibility. Wide power supply range of 19-300 Vdc or 40-250 Vac and a 50/60 Hz rating support global deployments, minimizing external conditioning and simplifying installation. Removable terminals and semi-flush mounting speed retrofit and service in the field, while conformal-coated boards protect against humidity and contaminants in harsh environments. Trip Coil Monitor and Zone Selective Interlocking (2) provide enhanced protection logic and selective tripping; built-in diagnostics support predictive maintenance and faster issue resolution. The Eaton warranty and support ecosystem offer assurance for long-term ROI, even as transformer protection requirements evolve with industry standards.
Get a Quick Quote for a Eaton ETR-4000-2A0EB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A0EB0?
Enquire Now
FAQs
Plan for a semi-flush mounting arrangement using the unit's removable terminals to simplify retrofit. Ensure a clean 19-300 Vdc or 40-250 Vac supply and 50/60 Hz environment. Verify Profibus-DP over RS-485 wiring for PLC/SCADA integration, and budget space for eight digital inputs and nine outputs to accommodate your protection logic and signaling needs.
Key specs include eight digital inputs, nine digital outputs, two current-sensing inputs, and a power-supply range of 19-300 Vdc or 40-250 Vac operating at 50/60 Hz. It supports Profibus-DP over D-Sub/RS-485, Trip Coil Monitor, and Zone Selective Interlocking with 2 zones, enabling fast, coordinated transformer protection and diagnostics.
Yes. The ETR-4000-2A0EB0 is designed for transformer protection in both substations and OEM equipment. It provides differential protection, metering capabilities, and network integration via Profibus-DP over RS-485, making it applicable to power distribution, OEM protection relays, and stackable protection architectures.
Compliances are not explicitly listed in the provided data; Eaton designates Compliances: Contact Manufacturer. To confirm CE, SIL, IP ratings, and region-specific certifications, consult the official Eaton specification sheet for ETR-4000-2A0EB0 or contact Eaton support.
The device’s built-in diagnostics, remote communication, and robust protection reduce downtime and maintenance overhead. With a 1-year warranty (or 18 months from shipment, per Eaton policy) and compatibility with existing networks, the ROI comes from faster fault isolation, reduced spare parts, and easier retrofit of legacy protection relays in transformer protection schemes.