Eaton transformer relay ETR-4000-2A0HB0 - 61850/TCP
Part Number: ETR-4000-2A0HB0
Quick Summary
Eaton transformer relay is a protection device that delivers transformer protection and monitoring for power networks and OEM equipment. Engineers often face nuisance trips and slow fault isolation when protection schemes aren’t tightly coordinated across devices. Compliances are provided by the manufacturer; confirm CE, SIL, or IP requirements with Eaton as needed. The ETR-4000-2A0HB0 supports IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, enabling seamless integration into modern substation automation and remote monitoring workflows, while offering wide input ranges and modular I/O to support scalable protection architectures.
Product Information
Extended Description
ETR-4000-2A0HB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A0HB0
UPC
786679155196
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Specification Sheet - ETR-4000-2A0HB0
The 8 digital inputs and 9 digital outputs enable robust signaling and interlock control, improving fault containment and reducing operational risk in transformer protection schemes. This translates to quicker isolation during faults and lower risk of collateral damage, which is critical in substations and industrial facilities. The dual power-supply range of 19-300 Vdc and 40-250 Vac provides flexible installation across diverse plant environments, reducing wiring complexity and guarding against supply-voltage issues. With 2 current sensing inputs and differential protection capabilities, operators gain precise fault detection and metering to support asset health monitoring and energy management goals. The I/O options include Trip Coil Monitor, URTD Interface, and IRIG-B time synchronization, which streamline protection coordination and time-stamped event logging for post-event analysis. Conformal-coated circuit boards and removable terminals simplify field maintenance and enhance reliability in harsh environments, while semi-flush mounting speeds up retrofits and panel installations. The 61850, M-Bus TCP, and DNP3 TCP/UDP communications ensure quick SCADA integration, reducing commissioning time and enabling remote diagnostics, trending, and alarm management. With Eaton’s base relay, the ETR-4000 series provides a proven foundation for transformer protection, metering, and monitoring in both new builds and refurbishments, aligning with industry standards and customer-specific protection philosophies.
Get a Quick Quote for a Eaton ETR-4000-2A0HB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A0HB0?
Enquire Now
FAQs
The relay features removable terminals and a semi-flush mounting method, enabling straightforward retrofit or new installation. With 8 digital inputs, 9 outputs, and a wide power supply range (19-300 Vdc, 40-250 Vac), it is compatible with common substation fault logic and OEM protection schemes. Use IEC 61850 or DNP3 TCP/UDP over Ethernet for SCADA integration and ensure wiring conforms to local protection coordination requirements.
Key specs include 2 current sensing inputs, 5 A / 1 A phase current ranges, 8 DI and 9 DO I/O with TRIP/COIL monitoring options, and supply compatibility across 19-300 Vdc and 40-250 Vac at 50/60 Hz. Communication options cover 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet RJ45, enabling robust protection logic, metering, and remote diagnostics.
Yes. The product is designed as a transformer protection relay with scalable I/O, Ethernet-based communication, and time-synchronization capabilities. Its differential protection and metering functions support reliable fault detection, while IRIG-B timing and Trip Coil Monitor IO enhance protection coordination in substations and OEM installations.
Compliance details are provided by the manufacturer. Verify CE, SIL, IP rating requirements with Eaton to ensure your specific installation meets regulatory and safety standards. If you have unique compliance needs, consult Eaton’s technical support for documentation and qualification testing.
The relay offers robust transformer protection with built-in metering, scalable I/O, and Ethernet communication that reduces commissioning time and enables remote diagnostics. Conformal coating improves reliability in harsh environments, while modular I/O supports future protection upgrades, leading to lower maintenance costs and enhanced asset uptime.