Eaton ETR-4000-2A0IB0 Transformer Relay - 50/60 Hz

Part Number: ETR-4000-2A0IB0
Manufacturer
Eaton
Part number
ETR-4000-2A0IB0

Quick Summary

ETR-4000 transformer relay from Eaton provides comprehensive transformer protection for switchgear, substations, and critical plant equipment. Engineers often struggle with coordinating precise trips while maintaining reliable communications across mixed RS-485 and Ethernet networks in demanding environments. Certifications and compliance are typically CE and UL marks with rugged IP-rated enclosures, and customers may require SIL readiness depending on the safety case. Equipped with eight digital inputs and nine digital outputs, a wide power range (19–300 Vdc / 40–250 Vac) and Modbus/DNP3 over RS-485 or TCP/IP, the ETR-4000 streamlines wiring, speeds commissioning, and improves protection coordination across transformer assets.

Product Information

Extended Description

ETR-4000-2A0IB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, , over RS-485, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A0IB0
UPC
786679153789
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
Flexible power and I/O architecture enables operation from 19–300 Vdc or 40–250 Vac, while eight digital inputs and nine outputs simplify wiring. This reduces panel clutter and minimizes the need for external I/O modules, cutting installation time and total cost of ownership. Use this in transformer protection schemes within substations and plant transformers to streamline commissioning and improve reliability. Communication and interoperability ensure seamless SCADA integration via RS-485 Modbus/DNP3 RTU and Ethernet TCP. The device supports remote monitoring, event logging, and coordinated protection actions across multiple feeders, reducing mean time to repair and enabling faster fault isolation. Protection features include current sensing with 5A/1A coils, differential protection, and Trip Coil Monitor with URTD Interface. This delivers selective tripping, precise fault localization, and enhanced fault recording with minimal nuisance trips. Installation benefits come from removable terminals and semi-flush mounting, plus conformal coated circuit boards that resist harsh environments. These touches simplify field service, extend life in dusty or humid spaces, and support quick upgrades without rewiring. Diagnostics and coordination options such as Zone Selective Interlocking (2) and IRIG-B timing provide robust protection in multi‑unit installations, improving system reliability and reducing coordination errors across transformer fleets.

Get a Quick Quote for a Eaton ETR-4000-2A0IB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A0IB0? Enquire Now

FAQs

The ETR-4000 supports Modbus RTU over RS-485 and Modbus TCP over Ethernet, enabling straightforward integration with current SCADA and automation systems. It provides eight digital inputs and nine digital outputs, with removable terminals for easy field wiring, and includes an IRIG-B Trip Coil Monitor interface for precise protection coordination.
This relay is designed for transformer protection in switchgear and substations, supporting differential protection and current sensing to ensure selective tripping. Zone Selective Interlocking (2) enhances coordinated protection across multiple units, reducing unnecessary outages and helping operators isolate faults quickly in complex transformer banks.
The device features removable terminals and semi-flush mounting, plus conformal coated circuit boards for harsh environments. Wide power supply range (19–300 Vdc / 40–250 Vac) simplifies sourcing, while compact wiring and modular I/O reduce commissioning time and facilitate future upgrades without major rewiring.
Warranty coverage follows Eaton’s policy, with one year from installation or eighteen months from shipment. The integrated diagnostics, Trip Coil Monitor, and remote communication options support proactive maintenance and faster fault diagnosis, contributing to reduced downtime and longer asset life when combined with routine SCADA monitoring.
The ETR-4000 operates with a power input range of 19–300 Vdc or 40–250 Vac at 50/60 Hz, and provides eight digital inputs plus nine digital outputs. It supports current sensing (5A/1A), removable terminals, and multiple communication options (RS-485 for Modbus/DNP3 and Ethernet for TCP/IP), enabling versatile transformer protection configurations.