Eaton ETR-4000-2A0LA1 Transformer Relay - 50/60 Hz
Part Number: ETR-4000-2A0LA1
Quick Summary
Eaton transformer relay protects transformer circuits in power distribution and industrial automation. Engineers often struggle to integrate protection relays with fiber Ethernet networks, risking slow fault diagnosis and extended downtime. Typical approvals to verify include CE marking, UL recognition, and IP ratings, with formal confirmation from the manufacturer. This model provides flexible communication interfaces, scalable I/O, and robust protection logic to support reliable transformer protection programs and asset optimization. Designed for cross-subsystem deployment, it supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber, 8 digital inputs, 9 digital outputs, and 2 current sensing inputs, enabling faster commissioning and reduced total cost of ownership.
Product Information
Extended Description
ETR-4000-2A0LA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A0LA1
UPC
786679153994
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Eaton Specification Sheet - ETR-4000-2A0LA1
Feature → Business Impact → Application: The ETR-4000-2A0LA1 delivers multi‑protocol communications with Mbus TCP or DNP3 TCP/UDP over LC duplex fiber optic ENet, enabling secure, high‑speed data exchange and easier integration with modern SCADA systems. This reduces fault‑diagnosis time and supports centralized protection logic for transformer networks in substations and data centers. Feature → Business Impact → Application: Eight digital inputs and nine digital outputs paired with two current sensing inputs provide a flexible protection and metering interface, enabling customized protection schemes and real‑time status reporting for critical transformers in manufacturing plants and utility corridors. Feature → Business Impact → Application: A wide power‑supply range—19–300 Vdc and 40–250 Vac—together with 50/60 Hz operation and removable terminals in a projection mount, simplifies retrofit projects and new installations, reducing cabinet space concerns and wiring complexity in control rooms and switchgear assemblies. Feature → Business Impact → Application: I/O options such as IRIG‑B, Trip Coil Monitor, and URTD Interface, plus zone selective interlocking (2), enhance coordination and fault isolation, enabling faster restoration and improved system reliability in distributed generation facilities and substations. Feature → Business Impact → Application: The unit’s robust physical design, combined with Eaton’s warranty and service policies, supports a lower total cost of ownership by simplifying maintenance planning and long‑term asset protection across multi‑site deployments.
Get a Quick Quote for a Eaton ETR-4000-2A0LA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A0LA1?
Enquire Now
FAQs
The ETR-4000-2A0LA1 uses removable terminals and a projection mounting method, simplifying wiring and field assembly. It supports 8 digital inputs, 9 outputs, and 2 current sensing inputs, allowing you to map protection logic to your existing scheme. For retrofit projects, plan the wiring harness, connector compatibility, and existing SCADA interfaces (Mbus TCP or DNP3 TCP/UDP) to minimize commissioning time.
This model offers current protection and metering with 2 current sensing inputs, 8 digital inputs, and 9 digital outputs to support differential protection, zone selective interlocking (2), and trap/fault signaling. It supports IRIG‑B, Trip Coil Monitor, and URTD Interface options for enhanced coordination. The 5A and 1A phase current ratings enable accurate protection settings for common transformer configurations.
Yes. The relay is designed for transformer protection within power distribution and industrial automation environments. Its Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet, 8 inputs and 9 outputs, and flexible power supply range make it adaptable to both substation and data-center protection schemes, with scalable I/O and remote monitoring capabilities.
The product data indicates ‘Compliances: Contact Manufacturer.’ Typical deployments verify CE, UL, and IP ratings as applicable to regional requirements. To confirm the exact certifications for your installation, consult Eaton’s specification sheets and the local compliance team before deployment to ensure alignment with your regulatory framework.
With removable terminals, projection mounting, and a robust I/O set, commissioning and field wiring are streamlined, reducing install time and human error. The protection relay’s integrated communication options (Mbus TCP, DNP3) simplify remote monitoring and diagnostics, contributing to lower maintenance costs and faster fault resolution, improving overall asset uptime and ROI.