Eaton ETR-4000-2A0LB1 Transformer relay - 40-250Vac
Part Number: ETR-4000-2A0LB1
Quick Summary
Eaton transformer relay is a high‑reliability protective device for transformers in power distribution and industrial automation. Engineers often struggle with false trips and slow fault detection when protection isn't coordinated with control networks. Key certifications to verify for mission‑critical installations typically include CE for European compliance, SIL ratings for safety‑related protections, and IP enclosure ratings for harsh environments; the data here notes that compliance should be confirmed with the manufacturer. Beyond protection, this unit supports remote monitoring via Mbus TCP or DNP3 over LC duplex fiber, enabling integrated asset management. With eight digital inputs and nine outputs and a wide power range, it fits a broad range of control architectures while improving uptime and safety.
Product Information
Extended Description
ETR-4000-2A0LB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A0LB1
UPC
786679155295
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B URTD Interface Trip Coil Monitor
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Eaton Specification Sheet - ETR-4000-2A0LB1
The Mbus TCP and DNP3 TCP/UDP communications run over LC duplex fiber optic Enet for secure, low‑latency data exchange, enabling fast fault notification and centralized monitoring in substations and industrial facilities. This feature reduces mean time to repair and enhances asset visibility, delivering measurable improvements in system reliability. The eight digital inputs and nine digital outputs provide flexible I/O for interlocking schemes, status signaling, and remote control, which translates into simpler wiring, easier expansion, and reduced installation costs for retrofit projects. Two current sensing inputs support precise transformer protection relies on differential and metering data, improving fault discrimination and lowering the risk of nuisance trips in dynamic load conditions. The unit’s 19‑300 Vdc / 40‑250 Vac power range ensures compatibility with diverse control architectures, simplifying procurement and installation across new builds and upgrades. Conformal coating and removable terminals improve field reliability and serviceability in harsh environments, enabling faster maintenance and longer service life. IRIG‑B URTD interface and Trip Coil Monitor options offer advanced synchronization and protection signaling for zone selective interlocking, supporting safer, more coordinated transformer protection strategies. Overall, the ETR‑4000 is designed to meet modern industry needs for reliability, connectivity, and safety in transformer protection and metering applications.
Get a Quick Quote for a Eaton ETR-4000-2A0LB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A0LB1?
Enquire Now
FAQs
The ETR-4000-2A0LB1 is designed for transformer protection in power distribution, substation, and industrial automation environments. It supports a broad input power range (19-300 Vdc, 40-250 Vac) and multiple communication options (Mbus TCP, DNP3 TCP/UDP over fiber), making it suitable for retrofit and new-build projects in harsh environments. Its removable terminals and conformal coating further ease installation and maintenance in challenging sites.
Integration is enabled through Mbus TCP and DNP3 TCP/UDP over LC duplex fiber Ethernet, providing secure, low‑latency data exchange for real-time monitoring and fault alarms. This allows SCADA or asset-management systems to receive protection status, metering data, and alarms, enabling faster decision‑making, improved situational awareness, and streamlined maintenance planning.
The unit includes eight digital inputs and nine digital outputs, with two current sensing inputs for protection and metering. I/O options include IRIG‑B, URTD interface, and Trip Coil Monitor. This configuration supports complex interlocking, signaling, and protection schemes, while removable terminals simplify field wiring and future upgrades in either new installations or retrofits.
Current product data notes Compliances as 'Contact Manufacturer,' so official CE, SIL, and IP ratings should be confirmed directly with Eaton. Verification before installation is recommended to meet regional regulatory requirements and safety standards. In mission-critical environments, requesting the latest certification documents ensures alignment with site safety programs and customer specifications.
Warranty terms specify Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. This reflects standard coverage for protection relays and supports scheduled maintenance. For extended service, renewal options or professional installation support can be discussed with Eaton or authorized distributors to maximize uptime and ensure proper configuration.