Eaton ETR-4000-2A1DA1 Transformer Relay - Profibus-DP

Part Number: ETR-4000-2A1DA1
Manufacturer
Eaton
Part number
ETR-4000-2A1DA1

Quick Summary

ETR-4000-2A1DA1 transformer relay provides comprehensive transformer protection and monitoring for industrial power systems. Engineers often struggle with reliable fault detection, fast trip coordination, and networked reporting in compact control panels. Compliance details should be confirmed with the manufacturer; public CE or SIL listings are not shown in the data, so verification is recommended. With Profibus-DP over fiber, eight digital inputs and nine outputs, and a wide power-supply range of 19-300 Vdc or 40-250 Vac, it scales from small to large transformer protection in plants, data centers, and utilities. This combination supports reduced downtime, improved operability, and easier integration with existing control architectures.

Product Information

Extended Description

ETR-4000-2A1DA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Profibus-DP , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor,Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A1DA1
UPC
786679154236
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Profibus-DP over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface Sensitive Ground Input IRIG-B
Phase current
5A, 1A
PROFIBUS-DP
over fiber optic ST
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
Feature: 8 digital inputs and 9 outputs enable comprehensive protection logic and streamlined wiring. Business impact: reduces panel complexity, shortens installation time, and enhances fault isolation. Application: ideal for transformer protection in industrial plants, substations, and data centers. Feature: Two current-sensing inputs (5A, 1A) support accurate protection and metering. Business impact: improves differential protection accuracy and fault localization, lowering false trips. Application: transformer protection schemes requiring precise current measurement in demanding environments. Feature: PROFIBUS-DP communication over fiber optic ST provides robust fieldbus connectivity. Business impact: high noise immunity and reliable remote monitoring across automation networks. Application: integration with plant controls and SCADA in manufacturing and utility facilities. Feature: I/O options including Trip Coil Monitor, URTD interface, Sensitive Ground Input, and IRIG-B time synchronization. Business impact: enhanced diagnostics, time-stamped events, and better fault analysis. Application: critical protection scenarios in substations and mission-critical equipment rooms. Feature: Zone Selective Interlocking with two zones improves selective tripping and reduces system-wide outages. Business impact: faster fault isolation and minimized service impact. Application: large transformer banks and complex feeder configurations in industrial networks. Feature: Removable terminals and projection mounting simplify installation and future maintenance. Business impact: faster commissioning, easier field upgrades, and reduced downtime during servicing. Application: retrofit projects and new builds where quick wiring and serviceability matter.

Get a Quick Quote for a Eaton ETR-4000-2A1DA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A1DA1? Enquire Now

FAQs

Installing the ETR-4000-2A1DA1 involves mounting the unit in a suitable panel with its projection mounting method and connecting the eight digital inputs and nine outputs to the transformer protection scheme. The terminals are removable for easier wiring, and the device seamlessly wires into existing Profibus-DP networks via fiber optic ST. Proper torque, cabling separation, and conformity to the Eaton installation guidelines ensure reliable operation and faster commissioning.
This relay supports current protection and metering, differential protection, and zone selective interlocking (two zones). It also offers Trip Coil Monitor and IRIG-B time synchronization, enabling accurate trip coordination and diagnostics. These features together reduce misoperations, accelerate fault isolation, and improve overall transformer reliability in challenging industrial environments.
Yes. The unit supports Profibus-DP over fiber optic ST, delivering reliable, EMI-resistant communication suitable for harsh plant conditions. This compatibility enhances remote monitoring, integration with SCADA, and easier distribution of protection logic across multi-bay transformer setups without sacrificing signal integrity.
The data provided lists Compliances as Contact Manufacturer, indicating that specific certifications (such as CE or SIL) should be confirmed directly with Eaton for your installation and regulatory requirements. Always verify with the manufacturer to ensure the product meets your local standards and approval processes prior to purchase or deployment.
The ETR-4000-2A1DA1 can lower total cost of ownership through reduced wiring complexity, faster commissioning, improved fault isolation, and fewer false trips thanks to precision current sensing and differential protection. Its removable terminals and projection mounting simplify maintenance, while a standard warranty supports long-term uptime and predictable service costs.