Eaton ETR-4000-2A1GA1 Transformer Relay - Modbus RTU/DNP3 RTU RS-485
Part Number: ETR-4000-2A1GA1
Quick Summary
Transformer relay from Eaton provides robust transformer protection for industrial power systems. Engineers often struggle to integrate protection relays into legacy control networks while maintaining reliable diagnostics and fast fault isolation. Compliances include CE marking and IP/SIL readiness depending on configuration; consult the manufacturer datasheet for exact certifications like CE, SIL, and IP ratings. This device supports Modbus RTU or DNP3 RTU over RS-485, with a flexible power range of 19-300 Vdc and 40-250 Vac, delivering scalable protection and monitoring. By aligning with standard industrial protocols, it delivers measurable business value through improved uptime, faster fault location, and easier SCADA integration.
Product Information
Extended Description
ETR-4000-2A1GA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A1GA1
UPC
786679154403
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor IRIG-B Sensitive Ground Input URTD Interface
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Eaton Specification Sheet - ETR-4000-2A1GA1
Eight inputs and nine outputs provide comprehensive protection logic at the device level, enabling precise tripping schemes and metering. This translates to faster fault discrimination and reduced nuisance trips in transformers and feeder circuits, especially in substations and industrial plants that require clear I/O mapping and quick diagnostics. The unit supports a wide power supply range of 19-300 Vdc and 40-250 Vac, simplifying integration with existing control systems and reducing stocking variety. Communication is flexible with Modbus RTU or DNP3 RTU over RS-485, enabling seamless integration with modern SCADA and protection schemes, which improves remote monitoring, fault analytics, and maintenance planning. I/O versatility includes Trip Coil Monitor, IRIG-B, Sensitive Ground Input, and URTD Interface, expanding synchronization, signaling, and trip verification for critical loads. Removable terminals and projection mounting streamline installation and field service, lowering commissioning time and wiring errors. Zone Selective Interlocking (ZSI) at level 2 supports fast, selective fault clearance, minimizing outage impact and improving grid stability in distributed transformer networks. This relay is designed for rugged industrial environments and offers compatibility with common protection schemes, supporting a modular approach to asset protection and lifecycle cost reduction.
Get a Quick Quote for a Eaton ETR-4000-2A1GA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A1GA1?
Enquire Now
FAQs
Begin by ensuring compatible power supply within 19-300 Vdc or 40-250 Vac. Use the removable terminals for clean pre-wiring, then mount via projection method for secure alignment. Connect Modbus RTU or DNP3 RTU over RS-485 to your SCADA network, and map the eight digital inputs and nine outputs to your protection logic. Verify wiring with the Eaton datasheet and perform a staged commissioning to minimize system downtime.
Yes. The unit is designed to operate with Modbus RTU or DNP3 RTU over D-Sub RS-485, enabling integration with diverse protection schemes. This flexibility simplifies SCADA integration, supports remote diagnostics, and reduces field visits by centralizing monitoring and event reporting within your existing control architecture.
Its 8 inputs and 9 outputs support complex protection logic, along with current sensing inputs and zone selective interlocking (ZSI) for selective fault clearance. The device handles 50/60 Hz operation and accepts a broad power supply range, which simplifies retrofits and upgrades in substations. The integration with RS-485 protocols allows seamless data exchange with protection relays and SCADA systems, enhancing reliability and response times.
Compliances are specified as Contact Manufacturer in the product data. For exact certifications such as CE marking, IP ratings, or SIL readiness, consult the ETR-4000-2A1GA1 datasheet or contact Eaton support to confirm model-specific approvals and any regional requirements prior to procurement.
Expect reduced downtime through faster fault isolation and improved fault visibility via remote diagnostics. The 8/9 I/O configuration supports precise protection schemes, while RS-485 communication streamlines SCADA integration, reducing commissioning time and field service visits. The removable terminals and projection mounting simplify maintenance, contributing to lower lifecycle costs and higher system availability.