Eaton transformer relay ETR-4000-2A1GB0 - Modbus RTU RS-485
Part Number: ETR-4000-2A1GB0
Quick Summary
The Eaton transformer relay ETR-4000-2A1GB0 provides transformer protection for utility and industrial power systems. Engineers often face integration challenges and need reliable protection across wide voltage ranges with scalable I/O. Certification details are not listed; consult Eaton for CE, SIL, or IP-rated approvals relevant to your region and application. By combining 8 digital inputs and 9 outputs with Modbus RTU or DNP3 RTU over RS-485, this device enables seamless SCADA integration and remote diagnostics, delivering faster fault isolation and reduced downtime. The solution supports OEM equipment, substations, and industrial plants, translating complex protection schemes into straightforward install-and-operate protection for modern automation.
Product Information
Extended Description
ETR-4000-2A1GB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz ,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A1GB0
UPC
786679154410
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface Sensitive Ground Input
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Specification Sheet - ETR-4000-2A1GB0
Selling Policy 25-000 - Distribution and Control Products and Services
Modbus RTU or DNP3 RTU over RS-485 enables seamless integration with existing SCADA and protection systems. This reduces wiring, simplifies configuration, and centralizes monitoring, delivering faster fault detection and improved operator visibility. Application: transformer protection in substations, OEM equipment, and industrial plants. Feature: Broad power supply range 19-300 Vdc, 40-250 Vac, 50/60 Hz. Benefit: supports diverse plant power architectures with a single device, lowering inventory and retrofit costs. Application: mixed-voltage facilities and upgrades. Feature: 8 digital inputs, 9 outputs, 2 current sensing inputs. Benefit: supports differential protection, metering, and zone selective interlocking; reduces reliance on external I/O modules and speeds diagnostics. Application: transformer control and protection circuits. Feature: Conformal coating, removable terminals, and semi-flush mounting. Benefit: enhances reliability in harsh environments and facilitates quick maintenance. Application: outdoor substations and rugged industrial environments. Feature: I/O options including IRIG-B Trip Coil Monitor URTD Interface and Sensitive Ground Input. Benefit: expands protection coordination and trip signaling capabilities for robust protection schemes. Application: protection schemes requiring precise timing and ground sensing. Warranty terms follow Eaton Selling Policy 25-000: one year from installation or 18 months from shipment, whichever occurs first.
Get a Quick Quote for a Eaton ETR-4000-2A1GB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A1GB0?
Enquire Now
FAQs
Install the relay on a semi-flush mounting surface using the removable terminals for quick maintenance. Connect power to the 19-300 Vdc / 40-250 Vac range, wire the eight digital inputs and nine outputs to the protection scheme, and configure Modbus RTU or DNP3 RTU over RS-485 for SCADA communication. Ensure proper grounding and verify protection logic with a test sequence before commissioning.
The unit supports Modbus RTU and DNP3 RTU communications over RS-485 via D-sub connectors, enabling integration with common industrial control systems and SCADA platforms. This interoperability helps streamline protection schemes and remote diagnostics without additional gateway hardware.
It accepts a dual-range power supply of 19-300 Vdc and 40-250 Vac, with a 50/60 Hz frequency rating. This broad range accommodates diverse plant electrical systems and simplifies retrofits by reducing the need for multiple supply modules.
Yes. The device features conformal coated circuit boards for increased moisture and contaminant resistance, plus removable terminals and semi-flush mounting for reliable operation and easier field maintenance in outdoor substations and rugged industrial settings.
Warranty terms follow Eaton Selling Policy 25-000: one year from installation or 18 months from shipment, whichever occurs first. For technical support, consult Eaton’s documentation or contact their regional support team to address commissioning questions or field issues.