Eaton transformer relay ETR-4000-2A1HB0 - 61850/Mbus TCP Ready

Part Number: ETR-4000-2A1HB0
Manufacturer
Eaton
Part number
ETR-4000-2A1HB0

Quick Summary

Eaton transformer relay ETR-4000-2A1HB0 provides advanced transformer protection for switchgear and substations. Engineers face integration challenges, remote diagnostics needs, and cyber-security pressures; this relay addresses those pain points with 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet. Industry practice emphasizes SIL-level reliability, CE-type readiness, and rugged IP-rated enclosures; this platform aligns with those expectations while offering diagnostic visibility. With a wide power-supply range and a flexible 8 inputs / 9 outputs configuration, it supports scalable protection schemes and easier retrofit across industrial networks. In short, it delivers robust transformer protection and streamlined protection-system integration for increased asset uptime and operational efficiency.

Product Information

Extended Description

ETR-4000-2A1HB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A1HB0
UPC
786679154496
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor Sensitive Ground Input URTD Interface IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
Feature: Ethernet-enabled protection communications including 61850, Mbus TCP, and DNP3 TCP/UDP over Enet RJ45. Business impact: Enables seamless integration with modern SCADA and substation automation systems, reducing engineering time and enabling centralized monitoring. Application: Ideal for retrofit projects and new builds where secure, interoperable transformer protection is required. Feature: 8 digital inputs and 9 digital outputs. Business impact: Flexible I/O supports complex protection logic, alarm signaling, and remote control without adding external interfaces. Application: Fits transformer feeders in packaged substations and distributed energy systems needing fast fault isolation. Feature: Wide power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz operation. Business impact: Accommodates both DC control circuits and AC control networks, simplifying panel design and reducing power-supply diversity. Application: Suitable for mixed-control environments and retrofits where voltage sources vary. Feature: I/O options including Trip Coil Monitor, Sensitive Ground Input, URTD Interface, and IRIG-B. Business impact: Improves protection integrity, ground sensing, time synchronization, and interface versatility. Application: Critical in transformer protection schemes requiring precise timing and fault-coordination. Feature: Protective-capability across Differential Protection and Current Protection and Metering. Business impact: Delivers early fault detection, accurate fault location, and enhanced metering for reliability and load optimization. Application: Essential for utility-grade transformer protection in substations and industrial power networks. Feature: Removable terminals and semi-flush mounting. Business impact: Simplifies installation, reduces commissioning time, and eases maintenance in tight panel spaces. Application: Retrofit and new-build installations where serviceability matters. Feature: Comprehensive documentation and compatibility through Eaton product sheets and specification PDFs. Business impact: Supports fast engineer onboarding, procurement alignment, and compliant project handoffs. Application: Useful for design reviews, QA, and commissioning workflows.

Get a Quick Quote for a Eaton ETR-4000-2A1HB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A1HB0? Enquire Now

FAQs

Plan mounting on a semi-flush surface and use the removable terminals to simplify wiring. Connect eight digital inputs and nine outputs according to your protection scheme, then power the unit from 19-300 Vdc or 40-250 Vac. Configure Ethernet communications for 61850, Mbus TCP, or DNP3 TCP/UDP over Enet RJ45. Label all signals clearly and verify proper grounding to ensure reliable protection and signaling during commissioning.
The relay supports 19-300 Vdc and 40-250 Vac power with 50/60 Hz operation, eight digital inputs, nine digital outputs, and two current sensing inputs. It provides 61850, Mbus TCP, and DNP3 TCP/UDP networking over Ethernet, and supports I/O options such as Trip Coil Monitor and IRIG-B. With 5A/1A phase current options, you can tailor protection logic for transformer feeders while maintaining compatibility with existing control infrastructure.
Yes, the ETR-4000-2A1HB0 is designed for transformer protection with current protection and metering, differential protection capabilities, and zone selective interlocking. Its Ethernet communications enable integration with modern SCADA and substation automation systems, while its wide input ranges support diverse control architectures. This makes it well-suited for both retrofit projects and new installations in substations and industrial power networks.
The product lists 'Compliances: Contact Manufacturer,' so verify applicable certifications with Eaton for your region and application. In practice, buyers typically consider SIL reliability, CE readiness, and IP or NEMA enclosure protection depending on environment and utility requirements. Plan for compatibility with your site’s safety and environmental standards and request formal certification documentation from Eaton as part of procurement.
The device carries Eaton’s warranty policy: 1 year from installation or 18 months from shipment, whichever occurs first. ROI benefits come from reduced downtime, faster fault isolation, and easier integration with modern protection schemes, supported by Ethernet-based diagnostics and remote monitoring. Ongoing maintenance can be simplified through centralized data access and compatibility with standard protection protocols, delivering long-term operational value.