Eaton ETR-4000-2A1LB1 Transformer protection relay - Mbus TCP / DNP3 over LC fiber
Part Number: ETR-4000-2A1LB1
Quick Summary
The Eaton transformer relay ETR-4000-2A1LB1 provides robust transformer protection and monitoring for industrial power systems. Operators often struggle with coordinating protection schemes across feeders, ensuring reliable communications, and maintaining uptime in harsh environments. While this model leverages 50/60 Hz operation and a broad power supply range, official certifications such as CE, SIL, or IP ratings should be verified on the Eaton datasheet. By integrating Modbus TCP and DNP3 TCP/UDP over LC duplex fiber Ethernet, it simplifies SCADA integration, reduces wiring complexity, and enhances remote diagnostics for proactive maintenance and faster fault isolation.
Product Information
Extended Description
ETR-4000-2A1LB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A1LB1
UPC
786679154953
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input URTD Interface
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Eaton Specification Sheet - ETR-4000-2A1LB1
Feature → Business Impact → Application: 8 digital inputs enable comprehensive supervisory control and status monitoring, reducing operator workload and supporting accurate fault diagnosis in real time across manufacturing lines. This improves asset uptime and reduces unplanned downtime, especially in critical feeders and transformers in substations or OEM equipment. Feature → Business Impact → Application: 9 digital outputs provide flexible control of protection logic and signaling, enabling precise interlocking and coordinated tripping schemes that minimize collateral damage during faults in power distribution networks. Application: suitable for transformer protection in SCADA-enabled plants seeking reliable remote operation. Feature → Business Impact → Application: 2 current sensing inputs allow accurate current-based protection and metering, delivering precise protection curves and energy accounting for performance analytics in grid-tied or isolated systems. Application: ideal for utilities and industrial facilities focusing on efficiency and loss reduction. Feature → Business Impact → Application: Power supply range of 19-300 Vdc and 40-250 Vac supports diverse installation environments, simplifying procurement and reducing spare-part inventories. Application: expedites field deployment in mixed-voltage environments. Feature → Business Impact → Application: Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet ensures robust, low-latency communications, enabling seamless integration with modern SCADA and historian systems. Application: long-distance plant networks and substations with hardened fiber rings. Feature → Business Impact → Application: IRIG-B Trip Coil Monitor and URTD Interface provide precise time stamping and test/diagnostic interfaces, improving protection coordination and post-event analysis. Application: critical protection corridors and renewable integration projects requiring accurate timing and diagnostics. Feature → Business Impact → Application: Zone Selective Interlocking (ZSI) capability of 2 zones enhances selective tripping, reducing arc flash exposure and improving system reliability. Application: large multi-feeder installations where fast, coordinated tripping minimizes system impact. Feature → Business Impact → Application: Conformal-coated circuit boards improve reliability in humid or corrosive environments, lowering maintenance costs and extending service intervals. Application: harsh industrial settings or coastal facilities. Feature → Business Impact → Application: Removable terminals and projection mounting simplify field installation and retrofit projects, reducing commissioning time and human error. Application: upgrades or replacements in legacy protection schemes. Feature → Business Impact → Application: 5A and 1A phase current sensing options allow flexible current transformer configurations, supporting diverse protection schemes and metering needs. Application: transformer protection for both utility-scale and industrial transformers.
Get a Quick Quote for a Eaton ETR-4000-2A1LB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A1LB1?
Enquire Now
FAQs
Begin with the projection mounting method and removable terminals for quick field wiring. Verify the 19-300 Vdc / 40-250 Vac power range and 50/60 Hz compatibility, then connect the 8 digital inputs and 9 digital outputs to your protection scheme. Use the fiber optic Ethernet link for reliable Modbus TCP and DNP3 communications to SCADA.
The unit supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber optic Ethernet, enabling robust remote monitoring and integration with modern SCADA systems. It also supports IRIG-B timing interfaces and URTD options for enhanced timing and test/diagnostic workflows.
Yes. The device accepts a wide power supply range of 19-300 Vdc and 40-250 Vac, and operates at standard 50/60 Hz. This flexibility simplifies installation across mixed power environments and reduces the need for multiple supply configurations.
The ETR-4000-2A1LB1 provides 2-zone ZSI, enabling selective tripping across feeders to minimize disturbance and arc-flash exposure. This improves overall system reliability and safety by isolating faults with the least impact while maintaining essential service continuity.
Eaton offers a standard warranty per policy 25-000: one year from installation or 18 months from shipment, whichever occurs first. For maintenance, rely on its conformal-coated boards and removable terminals to ease service, while the protected communications and diagnostics features support proactive maintenance and uptime tracking.