Eaton ETR-4000-2A2CA1 Transformer Relay - Modbus TCP

Part Number: ETR-4000-2A2CA1
Manufacturer
Eaton
Part number
ETR-4000-2A2CA1

Quick Summary

The Eaton transformer relay, ETR-4000-2A2CA1, provides robust transformer protection for industrial power networks and OEM equipment. This protection relay integrates current sensing, differential protection, and metering features to help you detect faults quickly and minimize downtime. Operators often struggle with integrating protection relays over Ethernet while maintaining accurate data collection and reliable communication. For procurement and field deployment, verify CE compliance and other relevant standards, and consider SIL-rated safety functionality and IP-rated environments where applicable. With Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45, you gain seamless interoperability with existing control systems, enabling streamlined maintenance, proactive diagnostics, and reduced engineering effort, along with scalable I/O for future expansion.

Product Information

Extended Description

ETR-4000-2A2CA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Trip Coil Monitor,Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2CA1
UPC
786679155073
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Sensitive Ground Input Trip Coil Monitor IRIG-B
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
Feature: Rich I/O and protection topology with 8 digital inputs and 9 digital outputs. Business Impact: Centralized monitoring and protection logic reduces external PLC complexity and provides quicker fault isolation. Application: Transformer protection within switchgear assemblies and OEM equipment where compact, integrated control is needed. Feature: Wide power-supply range (19-300Vdc, 40-250Vac). Business Impact: Enables global deployment across plants with varied electrical infrastructures, lowering site adaptation costs. Application: Multinational manufacturing facilities and utility-scale substations. Feature: Ethernet-based communication via Modbus TCP or DNP3 TCP/UDP over RJ45. Business Impact: Simplifies integration with existing SCADA and control networks, improving data visibility and reducing commissioning time. Application: OEMs and retrofits requiring seamless network interoperability. Feature: Two current-sensing inputs plus zone selective interlocking. Business Impact: Accurate protection coordination and fast fault clearance, improving system reliability and safety. Application: Transformer protection schemes with real-time metering and protection analytics. Feature: Removable terminals and projection mounting. Business Impact: Easier installation, field maintenance, and flexible retrofits with minimal downtime. Application: Retrofit projects and new installations in constrained electrical rooms.

Get a Quick Quote for a Eaton ETR-4000-2A2CA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A2CA1? Enquire Now

FAQs

Install the unit using its projection mounting method and removable terminals for quick field wiring. It provides 8 digital inputs and 9 digital outputs, enabling a compact yet comprehensive protection and control scheme. Plan for Ethernet network integration early, and verify the power supply sources match the 19-300Vdc or 40-250Vac range to ensure reliable operation from day one.
Key specs include 50/60 Hz operation, 2 current sensing inputs, 8 inputs and 9 outputs, and a wide power supply range of 19-300Vdc or 40-250Vac. It supports differential protection and metering, with Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45 for seamless network communication and remote diagnostics.
Yes. The relay is designed for Ethernet-based integration using Modbus TCP or DNP3 TCP/UDP over RJ45, enabling straightforward compatibility with modern SCADA systems and control networks. This reduces engineering effort during commissioning and provides reliable data exchange for monitoring and protection logic.
Compliances are listed as Contact Manufacturer, so verify with Eaton for CE marking, SIL ratings, IP/environmental ratings, and any country-specific certifications relevant to your installation. In practice, ensure your site’s safety and electrical standards are met and that the device’s certifications align with your risk assessment and regulatory requirements.
Expect improved protection coordination, faster fault isolation, and enhanced data availability from integrated metering and diagnostics. The Ethernet connectivity reduces commissioning time and simplifies maintenance, potentially lowering downtime costs and extending transformer life through proactive monitoring and timely intervention.