Eaton ETR-4000-2A2CB1 Transformer Relay - Modbus TCP

Part Number: ETR-4000-2A2CB1
Manufacturer
Eaton
Part number
ETR-4000-2A2CB1

Quick Summary

Eaton transformer relay is designed to protect and monitor power transformers in industrial and utility settings. It provides integrated protection logic, current protection and metering, and remote communication capabilities to reduce fault impact and downtime. This solution addresses the frequent challenge of transformer faults going undetected until severe damage or outages occur by delivering proactive monitoring and fast trip coordination. While explicit CE, SIL, or IP certifications are not listed in the datasheet, the unit relies on conformal-coated circuit boards and standards-aware interfaces to support harsh environments and safe integration with plant controls. With eight digital inputs, nine digital outputs, and a flexible power supply range of 19-300 Vdc or 40-250 Vac, it offers scalable protection without complicating installation.

Product Information

Extended Description

ETR-4000-2A2CB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Sensitive Ground InputTrip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2CB1
UPC
786679155097
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Sensitive Ground Input IRIG-B Trip Coil Monitor
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
Feature: 8 digital inputs and 9 digital outputs enable localized logic and signaling without external I/O modules. Business Impact: reduces wiring, panel space, and potential fault points while enabling faster protection decisions. Application: transformer protection schemes in substations or industrial plants. Feature: Power supply range of 19-300 Vdc / 40-250 Vac and 50/60 Hz compatibility. Business Impact: supports diverse plant power architectures and simplifies integration with existing electrical environments. Application: multi-plant deployment where varying voltages are present. Feature: Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45. Business Impact: seamless SCADA integration, remote monitoring, and centralized alerting. Application: data centers, utilities, and remote facilities seeking unified control. Feature: Differential Protection, Current Protection and Metering, plus Trip Coil Monitor and Zone Selective Interlocking. Business Impact: enhanced protection coordination, accurate fault detection, and faster clearance. Application: transformer feeders requiring precise discrimination and fast isolation. Feature: IO options including URTD Interface, Sensitive Ground Input, IRIG-B Trip Coil Monitor, and Conformal Coating. Business Impact: expanded diagnostics, broader compatibility, and reliability in harsh environments. Application: rugged industrial environments and safety-critical transformer protection tasks.

Get a Quick Quote for a Eaton ETR-4000-2A2CB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A2CB1? Enquire Now

FAQs

Plan for a front-access, projection-mounted enclosure; ensure 19-300 Vdc or 40-250 Vac supply is available; mount the unit with removable terminals for simplified wiring; connect 8 digital inputs and 9 digital outputs to the protection scheme; configure Modbus TCP or DNP3 TCP/UDP for SCADA integration; verify conformal coating suitability for the installation environment.
Key specs include 8 digital inputs, 9 digital outputs, power supply range of 19-300 Vdc / 40-250 Vac, 50/60 Hz operation, 5A/1A current sensing inputs, and the ability to support differential protection and current metering. Ensure system voltage, frequency, and communication protocols (Modbus TCP or DNP3) align with your plant controls and SCADA standards.
Yes. The ETR-4000-2A2CB1 is designed for transformer protection with differential protection, current protection and metering, trip-coil monitoring, and zone selective interlocking. Its Modbus TCP or DNP3 TCP/UDP interfaces enable integration with SCADA and data-center monitoring systems, supporting fast fault isolation and improved uptime.
The data sheet indicates Compliances as 'Contact Manufacturer', so verify CE, SIL, IP ratings, and related certifications directly with Eaton. Also confirm the device’s suitability for your regional regulatory requirements and ensure the conformal coating meets your environmental standards.
By consolidating protection logic, metering, and remote communication in a single device, the ETR-4000-2A2CB1 reduces wiring, panel space, and downtime during fault events. Its robust design and removable terminals ease maintenance and upgrades, delivering faster diagnostics and potentially lower lifecycle costs through improved transformer protection and SCADA visibility.