Eaton ETR-4000-2A2FA1 Transformer Relay - Modbus/DNP3 RTU
Part Number: ETR-4000-2A2FA1
Quick Summary
The Eaton transformer relay ETR-4000-2A2FA1 provides transformer protection for industrial power systems and switchgear deployments. Engineers often struggle with reliable protection logic, field diagnostics, and secure remote communications in harsh environments. Public certifications such as SIL, CE, or IP ratings are not listed in the datasheet; confirm these with Eaton to ensure regional compliance, safety, and interoperability with your existing approvals. With Modbus RTU or DNP3 RTU over fiber and a broad power input range, this unit supports scalable protection schemes, faster fault isolation, and easier installation for OEMs and integrators. In practice, you gain improved uptime, clearer diagnostics, and lower long-term maintenance costs.
Product Information
Extended Description
ETR-4000-2A2FA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Trip Coil Monitor,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2FA1
UPC
786679153741
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B Sensitive Ground Input
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - ETR-4000-2A2FA1
Selling Policy 25-000 - Distribution and Control Products and Services
Feature: Modbus RTU or DNP3 RTU over fiber optic ST communication. Business Impact: EMI immunity, secure data transfer, and reliable remote diagnostics. Application: ideal for transformer protection in substations and OEM equipment. Feature: 8 digital inputs, 9 digital outputs, and 2 current sensing inputs. Business Impact: flexible I/O enables integration with plant control and precise protection logic, reducing setup time and wiring errors. Application: retrofit and expansion in complex transformer protection schemes across utility and industrial sites. Feature: Wide power supply range 19-300 Vdc and 40-250 Vac, with 50/60 Hz frequency. Business Impact: universal compatibility with existing power rails and grid configurations, lowering customization costs. Application: installations ranging from backup circuits to main transformer protection panels. Feature: Protection suite including Current Protection and Metering, Differential Protection, and Zone Selective Interlocking (2). Business Impact: enhanced fault detection, accurate energy metering, and selective fault isolation, limiting downtime. Application: high-reliability transformer protection in critical substations and OEM equipment. Feature: I/O options such as URTD Interface, Trip Coil Monitor, IRIG-B, and Sensitive Ground Input. Business Impact: expanded signaling, precise time synchronization, and improved ground fault detection. Application: large-scale protection networks requiring robust synchronization and monitoring. Feature: Removable terminals and Projection mounting. Business Impact: faster installation, easier field maintenance, and simpler retrofits with minimized downtime. Application: OEM assemblies and retrofit projects in refurbished substations or new builds.
Get a Quick Quote for a Eaton ETR-4000-2A2FA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A2FA1?
Enquire Now
FAQs
Begin with verifying supply compatibility (19-300 Vdc; 40-250 Vac) and confirm 50/60 Hz operation. The device uses removable terminals and a projection mounting method, which simplifies conduit routing and field wiring. Plan for fiber optic wiring to support Modbus RTU or DNP3 RTU communication, and map the 8 digital inputs and 9 digital outputs to your control scheme to ensure quick, safe integration.
Yes, the unit supports Modbus RTU or DNP3 RTU over fiber optic ST, which provides EMI immunity and secure data transfer. This facilitates reliable remote monitoring, event logging, and faster fault diagnosis when connected to SCADA systems, reducing diagnostic time and improving overall system availability.
The relay includes Current Protection and Metering, Differential Protection, and Zone Selective Interlocking (2). These features enhance fault detection accuracy, enable selective isolation of faults, and provide precise metering for energy auditing, ultimately reducing downtime and damage to equipment in transformer protection scenarios.
The datasheet lists Compliances as 'Contact Manufacturer,' so public certifications like SIL, CE, or IP ratings are not specified here. For regulatory approvals, confirm with Eaton or review the latest datasheet to ensure compliance with your regional requirements and safety standards.
Warranty follows Eaton policy 25-000, offering one year from installation or eighteen months from shipment, whichever comes first. Regular maintenance should focus on verifying fiber communication integrity, testing digital I/O, and confirming protection logic settings after any system changes to sustain protection efficacy and minimize unplanned downtime.