Eaton ETR-4000-2A2GA1 Transformer Relay - Modbus/DNP3 RS-485
Part Number: ETR-4000-2A2GA1
Quick Summary
ETR-4000 transformer relay is a protective device that monitors transformer health and provides protection in industrial power systems. Engineers often grapple with configuring reliable protection, remote monitoring, and fast fault isolation across evolving substations. Typical certifications such as CE marking, SIL readiness, and IP-rated enclosures are supported depending on configuration; verify specifics with the manufacturer. This device supports Modbus RTU or DNP3 RTU over RS-485, 8 digital inputs, 9 digital outputs, and current metering, delivering robust transformer protection with scalable monitoring. It helps reduce downtime and maintenance costs while enabling seamless integration into existing automation architectures. A projection-mount design and flexible I/O options further improve installation efficiency and long-term reliability.
Product Information
Extended Description
ETR-4000-2A2GA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB/RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2GA1
UPC
786679154038
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input Trip Coil Monitor URTD Interface IRIG-B
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
E-series protective relays
E-series protective relays
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Eaton Specification Sheet - ETR-4000-2A2GA1
Feature: 8 digital inputs and 9 digital outputs enable comprehensive local control and status reporting. Benefit → Enables precise supervisory control and fault signaling, reducing misoperations and improving time-to-fault resolution. Application → Substation and plant protection schemes where clear digital signaling is required to coordinate protective actions across multiple devices. Long-tail keywords: transformer protection relay, digital I/O, protection signaling. Feature: 2 current sensing inputs support differential protection and metering. Benefit → Improves accuracy of transformer fault detection and energy accounting, supporting better asset management. Application → Critical transformer protection in medium to large installations. Feature: Wide power supply range (19-300Vdc, 40-250Vac) and 50/60 Hz compatibility. Benefit → Simplifies integration with existing power rails and eliminates the need for heavy engineering changes during upgrades. Application → New builds and retrofit projects across mixed AC/DC environments. Feature: Modbus RTU or DNP3 RTU over D-Sub/RS-485 communications. Benefit → Smooth SCADA/EMS integration, remote diagnostics, and centralized protection orchestration, reducing on-site labor. Application → Enterprise-wide monitoring and substation automation. Feature: I/O options including Sensitive Ground Input, Trip Coil Monitor, URTD Interface, and IRIG-B. Benefit → Flexible configuration for custom protective schemes and time synchronization, increasing situational awareness. Application → Complex protection tasks and communications with time-stamped events. Feature: Projection mounting and removable terminals. Benefit → Faster installation, easier maintenance, and reliable field connections with minimal downtime. Application → Field retrofits and new installations in tight equipment spaces.
Get a Quick Quote for a Eaton ETR-4000-2A2GA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A2GA1?
Enquire Now
FAQs
The unit uses a projection mounting method and removable terminals, which streamline field installation and maintenance. Plan for 19–300Vdc or 40–250Vac power, ensure RS-485 communication access for Modbus RTU or DNP3 RTU, and accommodate 8 digital inputs with 9 digital outputs for your protection scheme.
Yes. The relay communicates over RS-485 via D-Sub connections and supports both Modbus RTU and DNP3 RTU, enabling seamless integration with common SCADA and protection systems for remote monitoring and control.
It offers current protection and metering, differential protection capabilities, zone selective interlocking, and flexible I/O to support protective schemes. With 2 current sensing inputs and configurable digital I/O, it supports precise protection coordination and event logging.
The device supports a wide power range: 19–300 Vdc and 40–250 Vac, and it operates at standard 50/60 Hz, making it adaptable to mixed electrical environments and easier retrofits in existing plants.
Warranty is governed by Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. For certification and compliance details, confirm specific configurations with Eaton at the time of purchase.