Eaton ETR-4000-2A2HB0 Transformer Relay - 61850/DNP3 TCP
Part Number: ETR-4000-2A2HB0
Quick Summary
Introducing the Eaton transformer relay ETR-4000-2A2HB0, a transformer protection relay engineered for industrial plants and OEM equipment. It seamlessly supports 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet, simplifying integration in modern protection schemes. Engineers often struggle with protocol interoperability and timely fault isolation in noisy substation environments. This model mitigates those challenges with flexible communications, robust sensing, and rugged packaging. Key specs include 8 digital inputs, 9 digital outputs, and a power range of 19-300 Vdc or 40-250 Vac, enabling broad compatibility. Conformal coating and an industry-standard warranty further enhance reliability and total cost of ownership while preserving flexibility for future upgrades.
Product Information
Extended Description
ETR-4000-2A2HB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2HB0
UPC
786679154137
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input URTD Interface
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Specification Sheet - ETR-4000-2A2HB0
Selling Policy 25-000 - Distribution and Control Products and Services
Feature: Ethernet-enabled protection with 61850, Mbus TCP, and DNP3 TCP/UDP over Enet RJ45. Business impact: enables seamless cross-vendor protection coordination and faster deployment, cutting commissioning time in complex transformer protections. Application: transformer protection in substations and industrial plants requiring scalable, protocol-agnostic I/O. Feature: Broad power supply range 19-300 Vdc and 40-250 Vac with 50/60 Hz. Business impact: supports uniform design across mixed-grid environments, reduces auxiliary power conversion costs, and increases installation flexibility. Application: new builds and retrofit projects in utilities and process industries. Feature: 8 digital inputs, 9 digital outputs, plus 2 current sensing inputs; optional IRIG-B and URTD interfaces. Business impact: increases protection logic density and control precision, enabling zone selective interlocking and accurate metering without external hardware. Application: feeders and transformer banks in demanding environments. Feature: Conformal coating, removable terminals, and semi-flush mounting. Business impact: boosts reliability in harsh environments and simplifies field maintenance and upgrades. Application: outdoor substations and rugged industrial enclosures. Feature: Warranty and vendor support pathway with Eaton. Business impact: reduces maintenance risk and accelerates troubleshooting with easy serviceability. Application: long-term asset management and regulatory-ready installations.
Get a Quick Quote for a Eaton ETR-4000-2A2HB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A2HB0?
Enquire Now
FAQs
Plan for semi-flush mounting and ensure removable terminals for field wiring. Verify input power compatibility with a 19-300 Vdc or 40-250 Vac supply and confirm Ethernet-based communications (61850, Mbus TCP, DNP3). Allocate space for 8 digital inputs and 9 digital outputs and provide proper shielding to minimize electrical noise. Also account for warranty registration and the potential need for conformal coating in harsher environments.
Key specs include 8 digital inputs, 9 digital outputs, 2 current sensing inputs, and a 50/60 Hz operating frequency. It supports power inputs of 19-300 Vdc and 40-250 Vac, and communications via 61850, Mbus TCP, or DNP3 TCP/UDP over Ethernet RJ45. The device offers transformer protection features such as differential protection and zone selective interlocking with a robust form factor.
Ideal for substations, utility-scale transformers, OEM equipment, and industrial power systems requiring reliable transformer protection with flexible Ethernet communications. It fits retrofit projects and new builds where protocol interoperability and compact protection logic are priorities, enabling faster commissioning and easier integration with existing protection schemes.
The data specifies Compliances as Contact Manufacturer, so verify Eaton’s current certification status (such as CE) with the vendor. The device supports modern protection protocols (61850, Mbus TCP, DNP3), which are commonly required in regulated environments. Always confirm with Eaton for the latest compliance documentation before installation.
Warranty is Eaton Selling Policy 25-000, providing one year from installation or eighteen months from shipment, whichever occurs first. extended support and service options are available through Eaton’s channels. This reduces downtime risk, streamlines maintenance, and supports a lower total cost of ownership for transformer protection deployments.