Eaton ETR-4000-2A2HB1 Transformer Relay - 61850/DNP3

Part Number: ETR-4000-2A2HB1
Manufacturer
Eaton
Part number
ETR-4000-2A2HB1

Quick Summary

Eaton transformer relay protects power transformers and enables monitoring in switchgear and substations. Users today face challenges integrating multiple communication standards and field wiring complexity, which can slow commissioning and increase risk. Compliances are listed as Manufacturer to be confirmed; verify CE/SIL/IP ratings with Eaton for your region. The unit supports Ethernet-based protocols such as 61850, Mbus TCP, and DNP3 TCP/UDP over Enet RJ45, enabling scalable, secure protection schemes. This combination delivers reliable transformer protection with modern communications, helping engineers reduce downtime and improve asset visibility across the plant.

Product Information

Extended Description

ETR-4000-2A2HB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz, Projection
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2HB1
UPC
786679154144
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input URTD Interface Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
Feature → Business Impact → Application: 8 digital inputs and 9 digital outputs enable flexible control schemes for transformer protection logic, reducing panel space and wiring complexity while enabling precise interlocking. Application: medium-to-large transformer installations; Benefit: faster commissioning and easier maintenance. Feature → Business Impact → Application: 2 current sensing inputs support differential and fault current monitoring, improving protection accuracy and response times. Application: differential protection stages in substations; Benefit: improved selectivity lowers outage impact. Feature → Business Impact → Application: broad power supply range of 19-300 VDC or 40-250 VAC and 50/60 Hz compatibility streamline panel design and reduce power equipment inventory. Application: mixed-utility environments; Benefit: fewer power supply mismatches and simpler spare parts planning. Feature → Business Impact → Application: Ethernet communications including 61850, Mbus TCP, DNP3 TCP/UDP over RJ45 accelerate integration with modern SCADA and protection systems. Application: substation automation; Benefit: reduced engineering time and better real-time data access. Feature → Business Impact → Application: Conformal coating and removable terminals simplify harsh-environment installation and field service, improving uptime. Application: outdoor or damp environments; Benefit: longer service intervals and easier maintenance. Feature → Business Impact → Application: IRIG-B compatibility, URTD interface, and zone selective interlocking provide precise timing and fast fault isolation. Application: critical transformer banks; Benefit: enhanced safety and system reliability.

Get a Quick Quote for a Eaton ETR-4000-2A2HB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A2HB1? Enquire Now

FAQs

Start with mechanical mounting using the Projection method and connect the removable terminals for clean, service-friendly wiring. The unit provides 8 digital inputs and 9 outputs, plus 2 current sensing inputs; plan wiring to minimize loop area. Use URTD interface and IRIG-B options as required, and ensure the power supply is within 19-300 VDC or 40-250 VAC to avoid startup issues.
The relay supports Ethernet-based protocols including 61850, M-Bus TCP, and DNP3 TCP/UDP over RJ45. This enables seamless integration with SCADA and protection schemes, reduces engineering time, and provides standardized data models for fault analysis and transformer health monitoring across heterogeneous networks.
Yes. Designed as a transformer protection relay, it offers current protection and metering capabilities along with differential protection options. With 2 current sensing inputs and 8 DI/9 DO, it supports accurate fault detection, metering data capture, and reliable annunciation, making it well-suited for modern transformer protection applications.
The product lists Compliances as Contact Manufacturer, so formal CE, SIL, or IP ratings should be confirmed with Eaton for your specific region. For regulated environments, request certification documentation and a formal declaration of conformity from Eaton prior to installation to ensure compliance with local standards.
Warranty follows Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. For maintenance, rely on the removable terminals for serviceability, the conformal-coated circuit boards for rugged environments, and the URTD/IRIG-B options to support timing and remote monitoring, which collectively help reduce maintenance overhead and extend mean time between failures.