Eaton ETR-4000-2A2IB0 Transformer Relay - 50/60 Hz

Part Number: ETR-4000-2A2IB0
Manufacturer
Eaton
Part number
ETR-4000-2A2IB0

Quick Summary

The Eaton transformer relay is a robust protection device for industrial power networks. It delivers protective intelligence by monitoring transformer parameters and initiating appropriate actions to prevent faults. In practice, engineers often struggle with integrating multiple signals, achieving fast fault isolation, and simplifying wiring in dense panel layouts. This model consolidates eight digital inputs, nine digital outputs, and two current sensing inputs into a single unit with removable terminals for easier field upgrades. It supports Modbus/RTU over RS-485 and Modbus TCP over Ethernet, aiding modern control rooms, while its power ranges of 19–300 Vdc and 40–250 Vac simplify power planning. Exact certifications should be confirmed with Eaton, but the device is designed to meet typical industry expectations for transformer protection relays in 50/60 Hz systems, aligning with broader automation goals.

Product Information

Extended Description

ETR-4000-2A2IB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over RS-485, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2IB0
UPC
786679154205
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input IRIG-B URTD Interface Trip Coil Monitor
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
Feature → Business Impact → Application: The ETR-4000-2A2IB0 integrates eight digital inputs, nine digital outputs, and two current sensing inputs into a compact protection unit, reducing panel complexity and wiring costs while accelerating commissioning in transformer protection scenarios. This consolidation enables faster fault isolation and improved diagnostic visibility, which translates to lower downtime and higher availability in substations and industrial plants. The device offers RS-485 Modbus RTU and Ethernet Modbus TCP connectivity, enabling seamless integration with existing SCADA and PLC ecosystems, enhancing remote monitoring, data trends, and proactive maintenance programs. Its conformal-coated circuit boards and removable terminals support harsh environments and straightforward installation, while the power supply range (19–300 Vdc, 40–250 Vac) provides flexibility for diverse plant electrical systems. Zone selective interlocking and Trip Coil Monitor features further strengthen protection discipline and operator confidence.

Get a Quick Quote for a Eaton ETR-4000-2A2IB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A2IB0? Enquire Now

FAQs

Begin with the semi-flush mounting setup and secure the unit to the panel. Connect eight digital inputs, nine digital outputs, and two current sensing inputs to the corresponding field devices. Use removable terminals for quick wire termination, then configure power supply within 19–300 Vdc or 40–250 Vac. Establish communication via RS-485 Modbus RTU or Ethernet Modbus TCP to integrate with your PLC/SCADA system.
The relay supports current protection and metering, differential protection, zone selective interlocking, and Trip Coil Monitor. In fault conditions, the device executes protective logic to trigger appropriate tripping signals, isolates the transformer, and provides diagnostic data via Modbus TCP/RTU, enabling rapid operator action and minimized fault propagation in transformer circuits.
Yes. With 50/60 Hz operation, 8 DI / 9 DO I/O, RS-485 and Ethernet communications, and options like Sensitive Ground Input and IRIG-B, the ETR-4000-2A2IB0 is well-suited for transformer protection in both substations and motor control centers. Its modular I/O and robust mounting support reliable integration into standard industrial architectures.
Compliances are listed as Contact Manufacturer, so verify exact regulatory certifications (for your region) such as safety, EMC, and environmental ratings with Eaton. Confirm any SIL/CE/UL or IP rating requirements for your installation and ensure the unit meets your facility's compliance and safety documentation before deployment.
Maintenance benefits include reduced field visits through improved remote diagnostics via RS-485 and Ethernet, and the removable terminals simplify upgrades and servicing. ROI drivers include shorter downtime during fault conditions, faster fault isolation, and lower wiring complexity from a single integrated relay, all contributing to higher equipment availability and lower lifecycle costs.