Eaton transformer relay ETR-4000-2A2KB0 - 50/60 Hz
Part Number: ETR-4000-2A2KB0
Quick Summary
Eaton transformer relay protects transformers in industrial power systems. Engineers often struggle with reliable protection coordination and fast fault detection in live networks. Key certifications relevant to transformer protection relays include CE marking and SIL levels, with IP-rated enclosures available for challenging environments. This device combines robust protection with modular I/O and flexible communication options, delivering reliability and maintainability while enabling efficient integration with modern SCADA and digital maintenance workflows.
Product Information
Extended Description
ETR-4000-2A2KB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, , 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil MonitorSensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2KB0
UPC
786679154267
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input URTD Interface
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
0
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - ETR-4000-2A2KB0
8 digital inputs and 9 digital outputs enable comprehensive control and monitoring within a single relay. This consolidation reduces panel wiring, saves space, and minimizes wiring errors during installation. In transformer protection applications, the dense I/O simplifies sequencing, alarms, and interlocks. Two current sensing inputs support precise protection and metering, with phase currents selectable at 5A or 1A. This capability improves fault discrimination and reduces nuisance trips, essential in transformer protection schemes. Power supply range of 19-300 Vdc / 40-250 Vac with 50/60 Hz operation, plus removable terminals and semi-flush mounting, offers flexible installation and straightforward field wiring. Advanced I/O options and communications streamline integration with IRIG-B timing, Trip Coil Monitor, Sensitive Ground Input, URTD Interface, and Modbus/DNP3 TCP over LC duplex fiber Ethernet. Conformal coating enhances reliability in harsh environments, and a one-year warranty (or 18 months from shipment) reduces maintenance risk. Removable base compatibility and Eaton support simplify upgrades within existing protection architectures, ensuring quick commissioning and long-term compatibility with SCADA and protection schemes.
Get a Quick Quote for a Eaton ETR-4000-2A2KB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A2KB0?
Enquire Now
FAQs
Ensure the relay is mounted semi-flush with removable terminals for simplified wiring. Wire 8 digital inputs and 9 outputs, connect 2 current sensing inputs to appropriate CTs (5A/1A), and supply 19-300 Vdc or 40-250 Vac at 50/60 Hz. Use the provided connection diagrams and conformal coated boards to maintain reliability in industrial environments. The unit also supports Modbus/DNP3 TCP over LC fiber for panel-to-plant communications.
Key specs include 5A/1A phase current sensing, 8 inputs and 9 outputs, a power supply range of 19-300 Vdc and 40-250 Vac, and 50/60 Hz operation. It supports differential protection and current protection metering, with Modbus/DNP3 TCP communications and IRIG-B timing to ensure precise protection coordination and SCADA interoperability.
Yes. Its 8/9 I/O, 2 current sensing inputs, and support for Modbus/DNP3 TCP over fiber enable integration with distribution protection schemes and SCADA systems. The device’s flexible power options and mounting, together with differential protection features, help meet coordination requirements and minimize fault impact in feeder configurations.
Compliances are listed as 'Contact Manufacturer' on the data sheet, and typical Eaton E-Series relays support CE marking and SIL configurations depending on installation. IP ratings depend on enclosure design; verify the specific enclosure for your environment. Always confirm applicable standards with your compliance team prior to procurement and deployment.
The product carries Eaton’s warranty policy of one year from installation or eighteen months from shipment, whichever occurs first. The relay’s integrated I/O, removable terminals, and conformal coating reduce downtime and maintenance costs, while fiber-enabled communications and scalable protection features help lower long-term total cost of ownership in transformer protection applications.