Eaton ETR-4000-2A2KB1 Transformer Relay - 50/60 Hz

Part Number: ETR-4000-2A2KB1
Manufacturer
Eaton
Part number
ETR-4000-2A2KB1

Quick Summary

Eaton transformer relay protects transformers and monitors faults in industrial power systems. Engineers often face slow fault diagnosis and complex wiring when upgrading protection schemes across legacy installations. Certification considerations include CE compliance for European installations and UL/IEC references commonly cited in protective-relay datasheets; verify exact approvals from Eaton's datasheet. With 8 digital inputs, 9 outputs, and Modbus/DNP3 TCP communication, it integrates cleanly with modern SCADA and protection schemes, delivering faster fault isolation and better asset protection. This device supports transformer protection and metering functions with differential protection and meter inputs, enabling precise fault detection. The combination simplifies installation, enables future upgrades, and supports predictable maintenance windows.

Product Information

Extended Description

ETR-4000-2A2KB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, , 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground InputTrip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A2KB1
UPC
786679154274
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input IRIG-B URTD Interface Trip Coil Monitor
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
Feature: 8 digital inputs and 9 digital outputs enable direct sensing and control, reducing wiring complexity. Benefit: shorter panel build time and lower installation costs, while enabling robust trip coordination in transformer protection applications. Application: fits OEM equipment and retrofit projects requiring compact I/O for protection logic and metering in industrial plants. Long-tail keywords: transformer protection relay with digital I/O, Modbus TCP integration. Feature: Power supply range covers 19-300 Vdc and 40-250 Vac, supporting both DC and AC sources. Benefit: universal compatibility across new builds and legacy systems, minimizing power infrastructure changes. Application: ideal for mixed-power environments and equipment upgrades. Long-tail keywords: universal power supply transformer relays, AC/DC compatible protection devices. Feature: Removable terminals and projection mounting simplify installation and field service. Benefit: faster commissioning, easier retrofit, and reduced maintenance downtime. Application: panel design with scalable protection layouts. Long-tail keywords: removable terminal transformer relay, projection mounting protection relay. Feature: Conformal coated circuit boards withstand harsh industrial environments. Benefit: improved reliability and longer service life in dirty or humid facilities. Application: outdoor or challenging plant areas. Long-tail keywords: conformal coating protection relay, rugged transformer protection devices. Feature: Modbus/DNP3 TCP communication over LC duplex fiber optic Ethernet enables seamless SCADA integration. Benefit: fast, secure data exchange and easier fault diagnostics. Application: PLC/SCADA integration for centralized protection monitoring. Long-tail keywords: Modbus TCP transformer relay, DNP3 TCP protection devices, fiber optic Ethernet. Feature: I/O options include IRIG-B, Trip Coil Monitor, and Sensitive Ground Input for advanced protection schemes. Benefit: enhanced fault detection, time synchronization, and robust ground sensing. Application: zone selective interlocking and precision protection in complex transformer networks. Long-tail keywords: IRIG-B interface, trip coil monitor, zone selective interlocking.

Get a Quick Quote for a Eaton ETR-4000-2A2KB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-4000-2A2KB1? Enquire Now

FAQs

The device is designed for universal compatibility across the specified DC and AC ranges. Begin by mounting the unit in a projection-compatible panel, connect removable terminals per the wiring diagram, and assign the 8 digital inputs and 9 digital outputs to the process signals and interlocks. Use the IRIG-B and Trip Coil Monitor where required for enhanced protection schemes. Ensure proper grounding and verify the Modbus/DNP3 TCP network configuration for SCADA integration.
Key specs include the power supply range (19-300 Vdc / 40-250 Vac) and the operating frequency (50/60 Hz). The unit provides 8 digital inputs and 9 digital outputs, with removable terminals for ease of maintenance. It supports Modbus TCP and DNP3 TCP over fiber for industrial communications, and includes current sensing inputs (2) for protection logic. Confirm the exact configuration from the Eaton datasheet prior to installation.
Yes. With eight digital inputs, nine digital outputs, and flexible power options, it accommodates a wide range of protection and metering tasks, including zone selective interlocking and fast fault isolation. Its modular I/O and robust communication options simplify integration with existing SCADA systems, reducing downtime during fault events and easing future expansions.
Compliances are provided by the manufacturer; local approvals vary by region. Typical transformer protection relays reference CE marks and UL/IEC standards, but you should verify exact approvals on Eaton’s datasheet or contact Eaton directly to obtain the region-specific certification matrix for your installation site.
The device reduces maintenance downtime through removable terminals that simplify field servicing and upgrades. The integrated protection and metering reduce unplanned outages by enabling faster fault diagnosis. Additionally, SCADA integration via Modbus/DNP3 TCP enables centralized monitoring, improving asset uptime and potentially lowering total cost of ownership.